[ECTCR UFAS 4.17.4] EXCEPTION: Toe clearance at the front partition is not required in a compartment greater than 62 inches (1575 mm) deep with a wall-hung water closet or 65 inches (...
Search Results "Control End Wall"
-
604.8.1.4 Toe Clearance
-
Example 1: With Cooking Facilities
Fixed or Built-In: Appliance is attached to a cabinet, shelf, or wall; connected to plumbing or gas; or hardwired to electricity....
-
Showers
However, if a shower stall is not the only bathing facility provided in the dwelling unit, then the only specification for showers, appropriate under the Act, concerns reinforced walls in...
-
Rough Grade Site Inspection
along accessible routes, accessible parking and access aisles, etc. 11B-403 Verify if under-slab plumbing will provide adequate clearances from finished walls...
-
A4.30.1 GENERAL
Such cues include changes in illumination level, bright colors, unique patterns, wall murals, location of special equipment, or other architectural features (for example, an exterior view...
-
ii. Accessible scales
Stand-alone wheelchair scales include wall-mounted stationary (folding or not folding), platform (in ground), and portable platform (folding or not folding)....
-
Rough Grade Site Inspection
along accessible routes, accessible parking and access aisles, etc. 11B-403 Verify if under-slab plumbing will provide adequate clearances from finished walls...
-
4.20.4 Grab Bars
ADAAG specifications for grab bars vary slightly for bathtubs with in-tub and head of tub seats (the latter having longer bars on the sidewall and no bar on the head wall)....
-
Calculation of Percentages
For example, for the location of wheelchair accessible water closets (16” – 18” centerline from side walls or partitions), specifying to the midpoint of the range (17”) will accommodate...
-
11B-306.3.3 Minimum required depth
inches (203 mm) minimum increasing to 29 inches (737 mm) high minimum above the finish floor or ground at the front edge of a counter with a built-in lavatory or at the front edge of a wall-mounted...
-
11B-306.3.3 Minimum required depth
inches (203 mm) minimum increasing to 29 inches (737 mm) high minimum above the finish floor or ground at the front edge of a counter with a built-in lavatory or at the front edge of a wall-mounted...
-
604.8.1.4 Toe Clearance
EXCEPTION: Toe clearance at the front partition is not required in a compartment greater than 62 inches (1575 mm) deep with a wall-hung water closet or 65 inches (1650 mm) deep with a floor-mounted...
-
Notification Devices
Telephones must have volume control. Also, telephones must be served by an accessible outlet not more than 4 feet away to facilitate use of TTYs....
-
604 Water Closets and Toilet Compartments
Revisions to the requirements for water closets concern: location (604.2) clearance (604.3) grab bars (604.5) flush controls (604.6) dispensers (...
-
703.3.2 Position
EXCEPTION: Braille provided on elevator car controls shall be separated 3/16 inch (4.8 mm) minimum and shall be located either directly below or adjacent to the corresponding raised characters...
-
1(5) Accessible route
dwellings and a public or common use facility (including parking) exceeds 8.33%, or where other physical barriers (natural or manmade) or legal restrictions, all of which are outside the control...
-
4.10.13* Car Position Indicators
In elevator cars, a visual car position indicator shall be provided above the car control panel or over the door to show the position of the elevator in the hoistway....
-
Faucets [4.19.5]
with one hand operate without tight grasping, pinching, or twisting of the wrist require no more than 5 lbf to activate Lever-operated, push-type, and automatic controlled...
-
4.10.13* CAR POSITION INDICATORS
In elevator cars, a visual car position indicator shall be provided above the car control panel or over the door to show the position of the elevator in the hoistway....
-
16(a)(iv)
., permanently installed telephones shall have volume control and an accessible electrical outlet within 4 ft. of a telephone connection)....
-
Doors and Gates Operated Only By Security Personnel [§404.1, Ex]
This exception applies only where security personnel have sole control of doors or gates....
-
Restricted Entrances [§206.4.7]
Restricted Entrances [§206.4.7] If entrances are restricted to certain occupants on a controlled basis, at least one must comply in addition to public entrances required to be accessible...
-
11B-604.9.6 Dispensers
Dispensers shall not be of a type that controls delivery or that does not allow continuous paper flow....
-
11B-703.5.6 Height from finish floor or ground
Visual characters indicating elevator car controls shall not be required to comply with Section 11B-703.5.6. 2....