Where walls or partitions are not provided, the seat shall be positioned in a corner of the clear floor or ground space required by 5.3.2 for a left-hand or right-hand approach....
Search Results "Clear Floor Area"
Commonly Searched Documents
-
5.3.3.3 Location Where Walls Not Provided
-
1115B.3.2, Item 3
Exception: In an existing building, a single-accommodation toilet facility may have the water closet fixture located in an area which provides a clear space of not less than 36 inches (...
-
Exercise Equipment and Machines
Clear floor space must be positioned to allow a person to transfer from a wheelchair or to use the equipment while seated in a wheelchair....
-
Accessible Routes
Accessible routes inside the boundaries of play areas are addressed in the play area guidelines....
-
SETTLEMENT AGREEMENT BETWEEN THE UNITED STATES OF AMERICA AND PALACE SPORTS AND ENTERTAINMENT, LLC, REGARDING THE PALACE OF AUBURN HILLS
[See subsections ...]
-
M7
If the door swings into the room, does the door swing not overlap the required clear floor space for the toilet or lavatory?...
-
7c.
Is there clear maneuvering floor space in front of each accessible door (see Figure 25 in the appendix for measurements) and on the pull side, is there at least 18 inches clear floor space...
-
Transfer Access [1014.2.1]
One full, unobstructed side of the clear ground space must adjoin or overlap an ORAR or trail, as applicable, or another clear ground space....
-
11B-405.7.5 Doorways
Where doorways are located adjacent to a ramp landing, maneuvering clearances required by Sections 11B-404.2.4 and 11B-404.3.2 shall be permitted to overlap the required landing area....
-
g-iii
Is there clear maneuvering floor space in front of each accessible door (see ADA Standards § Fig. 25) and, on the pull side, is there at least 18 inches clear floor space beyond the latch...
-
106.5.41 Path of Travel
A continuous, unobstructed way of pedestrian passage by means of which the altered area may be approached, entered, and exited, and which connects the altered area with an exterior approach...
-
Circulation Paths
Objects that overhang circulation paths do not provide clear headroom....
-
1015.2 Where required
along open-sided walking surfaces, including mezzanines, equipment platforms, aisles, stairs, ramps and landings that are located more than 30 inches (762 mm) measured vertically to the floor...
-
11B-203.11 Water slides
An accessible route complying with Division 4 shall be provided to the ground- or floor-level entry points, where provided, of stairs, ladders, or other means of reaching the raised elements...
-
9.5 LOCKER ROOMS
Lockers in easily accessible areas must be provided for use by handicapped people....
- Scranton Toilet Partitions: Eclipse - Floor Mount Headrail
-
Swanstone Barrier-Free Shower Floor FBF-3464
Requires the Premium User plan or above. (Login or upgrade your account!)
-
ASI Global Partitions Floor Anchored/Overhead Braced
Requires the Premium User plan or above. (Login or upgrade your account!)
-
M9
Does the lavatory have at least a 29-inch-high clearance under the front edge and the top of the rim no more than 34 inches above the floor?...
-
4.2.1 General
In alterations, where a condition for exception in section 1.1 prohibits full compliance with a specific requirement for clear floor or ground space surface, slope, size, or location, the...
-
1118B.4
The minimum clear floor or ground space for wheelchairs may be positioned for forward or parallel approach to an object....
-
General: ADA Standard Section 211.1
Section 211.1 of the ADA Standards covers information in the current ADA Standards on scoping requirements for drinking fountains.
-
11B-203.13 Raised boxing or wrestling rings
An accessible route complying with Division 4 shall be provided to the ground- or floor-level entry points, where provided, of stairs, ladders, or other means of reaching the raised elements...