Extensions shall return to a wall, guard, or the landing surface, or shall be continuous to the handrail of an adjacent ramp run....
Search Results "Check Writing Surface"
-
505.10.1 Top and Bottom Extension at Ramps
-
Transition Plates
Transition Plates Transition plates are sloping pedestrian walking surfaces located at the end of a gangway....
-
R305.2 Placement
The placement of detectable warning surfaces shall comply with R305.2. Advisory R305.2 Placement. Some detectable warning products require a concrete border for proper installation....
-
Seating [4.32.2] and Knee Clearance [4.32.3]
The over-the-surface reach is limited to 25 inches if at least this much space is available below for knees and toes; (the forward seated reach may not extend beyond the toes)....
-
1018.10 Dune Crossings
The curbs or barriers are required to prevent the passage of a 2 inch diameter sphere, where any portion of the sphere is within 2 inches of the crossing surface....
-
11B-1009.5.2 Transfer space
A transfer space of 60 inches (1524 mm) minimum by 60 inches (1524 mm) minimum with a slope not steeper than 1:48 shall be provided at the base of the transfer platform surface and shall...
-
§ 38.119(b)
doorways of cars not operating at lighted station platforms shall have outside lights which, when the door is open, provide at least 1 foot-candle of illumination on the station platform surface...
-
§ 38.81(c)
(c) The doorways of vehicles not operating at lighted station platforms shall have outside lights which provide at least 1 foot-candle of illumination on the station platform or street surface...
-
11B-407.4.6.2.1 Size and shape
Buttons shall have square shoulders, be ¾ inch (19.1 mm) minimum in their smallest dimension and be raised 1/8 inch (3.2 mm) plus or minus 1/32 inch (0.8 mm) above the surrounding surface...
-
11B-1009.5.2 Transfer space
A transfer space of 60 inches (1524 mm) minimum by 60 inches (1524 mm) minimum with a slope not steeper than 1:48 shall be provided at the base of the transfer platform surface and shall...
-
1009.5.2 Transfer Space
A transfer space of 60 inches (1525 mm) minimum by 60 inches (1525 mm) minimum with a slope not steeper than 1:48 shall be provided at the base of the transfer platform surface and shall...
-
505.10.3 Bottom Extension at Stairs
Extension shall return to a wall, guard, or the landing surface, or shall be continuous to the handrail of an adjacent stair flight....
-
505.10.1 Top and Bottom Extension at Ramps
Extensions shall return to a wall, guard, or the landing surface, or shall be continuous to the handrail of an adjacent ramp run....
-
505.10.2 Top Extension at Stairs
Extensions shall return to a wall, guard, or the landing surface, or shall be continuous to the handrail of an adjacent stair flight....
- Williams Sound FM ADA KIT 37 - FM ADA Compliance Kit
- Stanley QDC 200 Series Grade 1 Heavy Duty Door Closers
- Corbin Russwin Inc. DC5000 Series Cam Action Door Closer
- Florestone 35-62H Barrier-Free Shower
- Neo-Metro Commercial Curved Front, Wall Mounted System M2 Basin 8980 Series
- Stanley QDC 300 Series Grade 1 Standard Duty Door Closers
-
4. c. CUSTOMER SERVICE and COMMUNICATION and ACCESS
Sensitizes people to appropriate terminology to use when speaking with, writing about or referring to people with disabilities....
-
Selecting a TTY
Since it can be difficult to write down information as it is read, the 2-line display can be helpful....
-
J. PHYSICAL CHANGES TO EMERGENCY SHELTERS
For shelters that are not owned or operated by the County, the County will request in writing that each of the owners and operators of the shelter facilities remove the noted barriers to...
-
III. IMPLEMENTATION AND ENFORCEMENT
The United States may review compliance with this Agreement at any time.If the United States believes that the City has violated this Agreement, the United States will notify the City in writing...