Exception: The enforcing agency may reduce the size of each required area of refuge to accommodate one wheelchair space that is not less than 30 inches by 48 inches (762 mm by 1219 mm) on floors...
Search Results "Input Floor"
-
1009.6.3 Size
-
Error/Omission: Adequate maneuvering clearance is not provided at doors, including doors to accessible toilet stalls.
The floor or ground area within the required clearances shall be level and clear. 4.17.5* Doors. Toilet stall doors, including door hardware, shall comply with 4.13....
-
Error/Omission: The shape of the door hardware requires tight grasping, pinching, and twisting of the wrist to use.
Hardware required for accessible door passage shall be mounted no higher than 48 in (1220 mm) above finished floor....
-
11B-307.2 Protrusion limits
Objects with leading edges more than 27 inches (686 mm) and not more than 80 inches (2032 mm) above the finish floor or ground shall protrude 4 inches (102 mm) maximum horizontally into...
-
11B-307.2 Protrusion limits
Objects with leading edges more than 27 inches (686 mm) and not more than 80 inches (2032 mm) above the finish floor or ground shall protrude 4 inches (102 mm) maximum horizontally into...
-
1009.6.3 Size
Exception: The enforcing agency may reduce the size of each required area of refuge to accommodate one wheelchair space that is not less than 30 inches by 48 inches (762 mm by 1219 mm) on floors...
-
11B-233.3.6 Graduate student and faculty housing at a place of education
including, but not limited to, the provisions in sections 233 and 809. 1) In sleeping rooms with more than 25 beds covered by this part, a minimum of 5% of the beds shall have clear floor...
-
11B-233.3.6 Graduate student and faculty housing at a place of education
including, but not limited to, the provisions in sections 233 and 809. 1) In sleeping rooms with more than 25 beds covered by this part, a minimum of 5% of the beds shall have clear floor...
-
11B-106.5 Defined terms
PIER BOAT LAUNCH RAMP BOAT SLIP BOTTLE FILLING STATION BUILDING BUILDING OFFICIAL CATCH POOL CCR CHARACTERS CHILDREN’S USE CIRCULATION PATH CLEAR CLEAR FLOOR...
-
11B-216.13.3 Conditions of use
Floor or wall coverings, floor or wall covering adhesives, carpets, formaldehyde-emitting particleboard cabinetry, cupboards or doors have not been installed or replaced in the previous...
-
Technical Memorandum TM 2017-25 Door and Gate Surfaces
TM 2017-25 Door and Gate Surfaces Effective Date: April 1, 2017 2012 TAS Reference: 404.2.10 404.2.10 requires door and gate surfaces within 10 inches (255mm) of the finish floor...
-
Lighting Contrast and Conceptual Design
And the whole [interior is] all white, clear white, everything white – the ceiling, the floor, the floor tiles, the wall, the columns, the furniture....
-
General [4.5.1]
Affected industries (floor finishes, ceramic tile, and plumbing fixtures) each employ a different testing method in designating the slip-resistance of their products....
-
11B-604.8.1.1 Size
shall be 60 inches (1524 mm) wide minimum measured perpendicular to the side wall, and 56 inches (1422 mm) deep minimum for wall hung water closets and 59 inches (1499 mm) deep minimum for floor...
- Panda S.10 All Aluminum Lift & Slide System
-
More Than Just Fruit Salad: A Beginner's Guide to the Charming Chaos of Watermelon Puzzles
The game is controlled with simple inputs: often just directional controls or a tap to select a drop location....
- PEMKO 7" Half Saddle/Offset Saddle Threshold No. 2727
- PEMKO 5 1/2" Half Saddle/Offset Saddle Threshold No. 158
- Sunlighten Community Solocarbon® Far Infrared Sauna
- Aurora Doors Sliding Barn Door
- Inclinator VL Vertical Platform Lift
- CRL-Blumcraft® Panic Handles 08 7100
-
307.2 Protrusion Limits
Objects with leading edges more than 27 inches (685 mm) and not more than 80 inches (2030 mm) above the finish floor or ground shall protrude 4 inches (100 mm) maximum horizontally into...
-
11B-307.2 Protrusion limits