Section 502 addresses car parking spaces and van parking spaces....
Search Results "Centered Clear Floor Space"
Commonly Searched Documents
-
502 Parking Spaces
-
405.9.1 Extended Floor or Ground Surface
The floor or ground surface of the ramp run or landing shall extend 12 inches (305 mm) minimum beyond the inside face of a handrail complying with 505....
-
Transfer Access [1014.2.1]
One full, unobstructed side of the clear ground space must adjoin or overlap an ORAR or trail, as applicable, or another clear ground space....
-
11B-703.8.9 Height above floor
11B-703.8.9 Height above floor. Low resolution VMS characters shall be 40 inches (1016 mm) minimum above the floor of the viewing position, measured to the baseline of the character. ...
-
11B-703.8.9 Height above floor
11B-703.8.9 Height above floor. Low resolution VMS characters shall be 40 inches (1016 mm) minimum above the floor of the viewing position, measured to the baseline of the character....
-
7. Amend 28 CFR part 35 by adding § 35.138 to read as follows:
7. Amend 28 CFR part 35 by adding § 35.138 to read as follows:
-
§ 35.138 Ticketing
§ 35.138 Ticketing.
-
§ 36.302(f)(1)(ii) Ticket sales
(ii) Ticket sales. A public accommodation that sells tickets for a single event or series of events shall modify its policies, practices, or procedures to ensure that individuals...
-
Location and Dispersion
[See subsections ...]
-
904.4 Sales and Service Counters
reduction of the number of existing mail boxes, the counter shall be permitted to have a portion which is 24 inches (610 mm) long minimum complying with 904.4.1 provided that the required clear...
-
904.4 Sales and Service Counters
reduction of the number of existing mail boxes, the counter shall be permitted to have a portion which is 24 inches (610 mm) long minimum complying with 904.4.1 provided that the required clear...
-
Angled Van Spaces
As with regular accessible spaces, van accessible spaces can share a common access aisle....
-
7c.
Is there clear maneuvering floor space in front of each accessible door (see Figure 25 in the appendix for measurements) and on the pull side, is there at least 18 inches clear floor space...
- McGuire VA Medical Center 3-D Printing Program to Assist Veterans in Rehabilitation
- Signaids Floor Numbering and Stair Shaft Designation-Style 2
- Signaids Floor Numbering and Stair Shaft Designation-Style 1
-
g-iii
Is there clear maneuvering floor space in front of each accessible door (see ADA Standards § Fig. 25) and, on the pull side, is there at least 18 inches clear floor space beyond the latch...
-
302 Floor or Ground Surfaces
Section 302 requires floor or ground surfaces to be stable, firm, and slip resistant and provides specifications for carpets and surface openings. Comment....
-
5.3.3.3 Location Where Walls Not Provided
Where walls or partitions are not provided, the seat shall be positioned in a corner of the clear floor or ground space required by 5.3.2 for a left-hand or right-hand approach. ...
-
5.3.3.3 Location Where Walls Not Provided
Where walls or partitions are not provided, the seat shall be positioned in a corner of the clear floor or ground space required by 5.3.2 for a left-hand or right-hand approach....
-
11B-233.3.1.2.3 Ground floors above grade
Where the first floor in a building containing residential dwelling units is a floor above grade, all units on that floor shall be adaptable....
-
11B-233.3.1.2.3 Ground floors above grade
Where the first floor in a building containing residential dwelling units is a floor above grade, all units on that floor shall be adaptable. ...
-
11B-805 Medical care and long-term care facilities
The operable parts requirements in Section 11B-309 and the maneuvering clearances and clear space requirements in Section 11B-404.2.4 apply only to the normal use of doors required to be...