The audio output shall provide verbal instruction for the user to press the accessibility function button as a response to verbal direction in order to select the destination floor....
Search Results "Ground Floor Exit"
-
11B-411.2.1.7.2 Assignment by touch screen hall call console
-
Performance and the Surface Deficiency Score
An SDS of 0 shows no interruption of the accessible route or clear floor space at the location. An SDS maximum 4 could potentially be awarded at each location. ...
-
1015.6 Slope
This section requires the slope of the surface of the clear ground space and turning space to not be steeper than 1:48 in any direction....
-
F213.1 General
A pit toilet is a primitive outhouse consisting of a toilet riser over a hole dug into the ground or receptacle to receive and naturally decompose human waste....
- TownSteel ED1300 Grade 1 Concealed Vertical Rod Panic Device
- Aqua Creek Scout Excel
- Behavioral Safety Products #TH870 Suicide Resistant Towel Hook - Front Mount
- Mighty 400 Pool & Spa Access Lift
-
Transfer Type Shower Compartments: ADA Standard Section 608.5.1
Section 608.5.1 covers the current ADA Standards for controls in transfer type shower compartments.
-
11B-604.9.5 Flush controls
Hand operated flush controls shall comply with Sections 11B-309.2 and 11B-309.4 and shall be installed 36 inches (914 mm) maximum above the finish floor....
-
11B-608.5.1 Transfer type shower compartments
compartments, the controls, faucets, and shower spray unit shall be installed on the side wall opposite the seat 38 inches (965 mm) minimum and 48 inches (1219 mm) maximum above the shower floor...
-
11B-608.5.1 Transfer type shower compartments
compartments, the controls, faucets, and shower spray unit shall be installed on the side wall opposite the seat 38 inches (965 mm) minimum and 48 inches (1219 mm) maximum above the shower floor...
-
11B-604.9.5 Flush controls
Hand operated flush controls shall comply with Sections 11B-309.2 and 11B-309.4 and shall be installed 36 inches (914 mm) maximum above the finish floor....
-
1134A.4 Sufficient maneuvering space
required to be adaptable shall provide sufficient maneuvering space for a person using a wheelchair or other mobility aid to enter and close the door, use the fixtures, reopen the door and exit...
-
New Provisions for Employee Work Areas
The proposed rule required such areas to be on an accessible route so that people with disabilities could approach, enter, and exit the space....
-
1133B.2.5.1
SECTION 1133B GENERAL ACCESSIBILITY FOR ENTRANCES, EXITS AND PATHS OF TRAVEL 1133B.2 Doors. 1133B.2.5.1 Door closer. ...
-
The September 11, 2001 Wake-up Call
We need to be proactive, and rely as much as possible on ourselves (and not to count on others), to find the exits and to make decisions about our safety....
-
Employee Work Areas [§206.2.8]
However, these types of employee work areas still must be accessible for “approach, entry, and exit” (§203.9)....
-
11B-1008.2.5.3 Handrails
Exceptions: Handrails shall not be required on ramps located within ground level use zones. Handrail extensions shall not be required....
-
1008.2.5.3 Handrails
Handrails shall not be required on ramps located within ground level use zones. 2. Handrail extensions shall not be required....
-
F - number system
F - number system The F - number system, ASTM E 1155, Standard Test Method for Determining FF Floor Flatness and FL Floor Levelness Numbers, was developed primarily to aid in the construction...
-
217.4.2.1 Public Buildings
Where at least one public pay telephone is provided on a floor of a public building, at least one public TTY shall be provided on that floor....
-
217.4.2.2 Private Buildings
Where four or more public pay telephones are provided on a floor of a private building, at least one public TTY shall be provided on that floor....
-
1010.1.9.7 Delayed egress locks
An attempt to egress shall initiate an irreversible process that shall allow such egress in not more than 15 seconds when a physical effort to exit is applied to the egress side door hardware...