Sections 236 and 206.2.13 of the 2004 ADAAG require one of each type of fixed exercise machine to meet clear floor space specifications and to be on an accessible route....
Search Results "Floor Destination Indicator"
Commonly Searched Documents
-
Exercise machines. (Section-by-Section Analysis)
-
A. Accessible Counters
.: where no direct service is provided) accessible, providing a 27" high knee space, at least 19" deep, with table/counter tops at 28"-34" above the floor and split proportionately between...
-
4.13.6 MANEUVERING CLEARANCES AT DOORS
The floor or ground area within the required clearances shall be level and clear....
-
Width [4.7.3] and Surface [4.7.4]
Curb ramp surfaces, including flared sides, must comply with requirements in 4.5 for ground and floor surfaces be "stable, firm, and slip resistant."...
-
4.34.5.5(2) Seat
The seat shall be 17 in to 19 in (430 mm to 485 mm) high measured from the bathroom floor and shall extend the full depth of the stall....
-
Horizontal Exits [IBC §1021 (2003), §1005.3.5 (2000)]
allowing occupants to exit the area containing the origin of a fire into another portion of the building that is protected by fire-resistance-rated assemblies (doors, walls, ceilings, and floors...
-
11B-605.4 Flush controls
Hand operated flush controls shall comply with Section 11B-309 except that the flush control shall be mounted at a maximum height of 44 inches (1118 mm) above the finish floor....
-
1132A.4, Item 3
Changes in height greater than ½ inch (12.7 mm) shall be accomplished by means of a ramp complying with Section 1114A or by means of a platform constructed to the level of the floor as illustrated...
-
Text Telephones (TTY)
Section 217.4.2 of the 2010 Standards requires that a building or facility provide a public TTY on each floor that has four or more public telephones, and in each telephone bank that has...
-
RECOMMENDED CHANGE
medical devices, requires a similar instability test in section 9.4.2.3: ME EQUIPMENT having a mass of 25 kg or more, other than FIXED ME EQUIPMENT that is intended to be used on the floor...
-
Examination Tables
Treatment tables typically have a fixed height of 31 inches measured from the floor to the top of the table. The lower cost products have an open base with an H-brace or shelf....
-
II-6.2100 General
If ADAAG is chosen, however, public entities are not entitled to the elevator exemption (which permits certain buildings under three stories or under 3,000 square feet per floor to be constructed...
-
ACCESSIBLE DWELLING UNITS
Requires the Accessibility Specialist plan or above. (Login or upgrade your account!)
- Mansfield Toilet ADA Commercial Package CP-1313
- Cybex Total Access Treadmill
-
Shower Spray Unit
However, comments from the plumbing industry indicated that the requirement, as worded, would pose cross connections and thermal shock hazards and would conflict with model codes and industry...
-
Slope
The commenter stated the definition indicates that slope is calculated based on the distance and elevation between two points....
-
Using the Polling Place Checklist
When completed, the checklist should provide an indication of the level of accessibility at the polling place....
-
Comparison: 2010 and 1991 ADA Standards for Accessible Design - Scoping Requirements
Scoping indicates what needs to be accessible and how many e.g., At least 60% of all public entrances need to comply with 404....
-
3.3.11 180-Degree Turn
* indicates data plotted in the graph Figure 3-11. 180-degree turning width: research findings versus the standards....
-
Rear Grab Bar
The proposed rule included provisions that make clear floor space requirements at water closets more stringent by not allowing other fixtures, such as lavatories to overlap the space....
-
404.2.7 Door and Gate Hardware
Operable parts of such hardware shall be 34 inches (865 mm) minimum and 48 inches (1220 mm) maximum above the finish floor or ground....
-
404.2.7 Door and Gate Hardware
Operable parts of such hardware shall be 34 inches (865 mm) minimum and 48 inches (1220 mm) maximum above the finish floor or ground....
-
11B-805 Medical care and long-term care facilities
A 30-inch by 48-inch clear floor space, in compliance with Section 11B-305, shall be centered in front of the display screen....