Habitable spaces in dwelling units and sleeping units in Group R-1 and R-2.1 occupancies in accordance with Table 907.5.2.3.2 shall be provided with visible alarm notification....
Search Results "Visual Mode"
Commonly Searched Documents
-
[F] 907.5.2.3.2 Groups R-1 and R-2.1
-
11B-809.5.3 Interconnection
The same visible alarm appliances shall be permitted to provide notification of residential dwelling unit smoke detection, building fire alarm activation, and carbon monoxide...
-
11B-215.3 Employee work areas
Where employee work areas have audible alarm coverage, the wiring system shall be designed so that visible alarms complying with Chapter 9, Section 907.5.2.3.1 Exception can be...
- Access Board: Signs
- Figure 407.2.3.2 Car Designations on Jambs of Destination-Oriented Elevator Hoistway Entrances – Drawing from the U.S. Access Board
-
Route and Destination Signs
Requirements for route and destination signs are subject to specifications for visual signs in section 703, including character height (810.6.2)....
-
§27.71(k)(3)(ii) Timing.
Where a timed response is required, the user must be alerted visually and by touch or sound and must be given the opportunity to indicate that more time is required;...
-
§ 27.71(k)(3)(ii) Timing
Where a timed response is required, the user must be alerted visually and by touch or sound and must be given the opportunity to indicate that more time is required;...
-
Style: ADA Standard Section 703.5.3
Characters shall be conventional in form. Characters shall not be italic, oblique, script, highly decorative, or of other unusual forms.
-
Exit Doors: ADA Standard Section 216.4.1
Section 216.4.1 covers scoping requirements in the current ADA Standards for signs at exit doors.
-
11B-216.6 Entrances
In existing buildings and facilities where not all entrances comply with Section 11B-404, entrances complying with Section 11B-404 shall be identified by the International Symbol of...
-
11B-703.5.3 Style
Characters shall be conventional in form. Characters shall not be italic, oblique, script, highly decorative, or of other unusual forms.
-
11B-216.4.1 Exit doors
Signs required by Chapter 10, Section 1013.4 at doors to exit passageways, exit discharge, and exit stairways shall comply with Sections 11B-703.1, 11B-703.2, 11B-703.3, and...
-
§382.69 What requirements must carriers meet concerning the accessibility of videos, DVDs, and other audio-visual presentations shown on-aircraft to individuals who are deaf or hard of hearing?
[See subsections ...]
-
11B-216.4.2 Areas of refuge and exterior areas for assisted rescue
Signs required by Chapter 10, Section 1007.11 to provide instructions in areas of refuge shall comply with Section 11B-703.5 _|Signs; Visual Characters|_....
-
Re: 216.6 Entrances
216.6 Entrances. Where not all entrances comply with 404, entrances complying with 404 shall be identified by the International Symbol of Accessibility complying with 703.7.2.1....
-
Re: 216.6 Entrances
216.6 Entrances. Where not all entrances comply with 404, entrances complying with 404 shall be identified by the International Symbol of Accessibility complying with 703.7.2.1....
-
11B-703.8.4 Character height
11B-703.8.4 Character height. The uppercase letter “I” shall be used to determine the allowable height of all low resolution VMS characters of a font. Viewing distance shall be...
-
407.4.8.1.1 Size
Characters shall be ½ inch (13 mm) high minimum.
-
[F] 907.5.2.3.1 Public and common use areas
[F] 907.5.2.3.1 Public and common use areas. Visible alarm notification appliances shall be provided in public use areas and common use areas, including but not limited...
-
11B-407.4.8.1.1 Size
Characters shall be ½ inch (12.7 mm) high minimum.
-
407.4.8.1.1 Size
Characters shall be 1/2 inch (13 mm) high minimum.
-
407.4.8.1.1 Size
407.4.8.1.1 Size. Characters shall be ½ inch (13 mm) high minimum.
-
Character Height [4.30.3]
Character Height [4.30.3] Characters must be sized according to the viewing distance although a minimum 3 inch upper case or capital letter height is required for overhead signs...