A clear floor or ground space complying with 305 shall be provided at each kitchen appliance. Clear floor or ground spaces shall be permitted to overlap....
Search Results "Usable Kitchen (FHA)"
-
804.6.1 Clear Floor or Ground Space
-
Section 1193.33 Information, documentation and training [1193.25 in the NPRM] (Section-by-Section Analysis)
The specific alternate format or mode to be provided is that which is usable by the customer....
-
1133A.2.1, Item 3
All other kitchen designs shall provide a minimum clear width of at least 48 inches (1219 mm). (See Figure 11A-10A)....
-
1133A.2.1, Item 3
All other kitchen designs shall provide a minimum clear width of at least 48 inches (1219 mm). (See Figure 11A-10A)....
-
11B-804.6.1 Clear floor or ground space
A clear floor or ground space complying with Section 11B-305 shall be provided at each kitchen appliance. Clear floor or ground spaces shall be permitted to overlap....
-
1133A.5 Lower shelving
Lower shelving and/or drawer space shall be provided in the kitchen at a height of no more than 48 inches (1219 mm) above the floor....
-
11B-804.6.1 Clear floor or ground space
A clear floor or ground space complying with Section 11B-305 shall be provided at each kitchen appliance. Clear floor or ground spaces shall be permitted to overlap....
-
11B-804.6.1 Clear floor or ground space
A clear floor or ground space complying with Section 11B-305 shall be provided at each kitchen appliance. Clear floor or ground spaces shall be permitted to overlap....
-
804.6.1 Clear Floor or Ground Space
A clear floor or ground space complying with 305 shall be provided at each kitchen appliance. Clear floor or ground spaces shall be permitted to overlap....
-
1133A.4.1, Item 4
4. Finished flooring shall be extended to the wall beneath the sink and work surface.
-
11B-809.9.5 Lower shelving
Lower shelving and/or drawer space shall be provided at a height of 48 inches (1219 mm) maximum above the finish floor.
-
§1193.33 Information, documentation, and training.
[See subsections ...]
-
Section 1193.33 Information, Documentation, and Training (Advisory Guidance)
Section 1193.33 Information, Documentation, and Training
- American Standard Cadet 2-Handle High-Arc Bar Sink Faucet 2475F
-
When must manufacturers and service providers evaluate access needs?
Manufacturers and service providers must evaluate the accessibility, usability and compatibility of their equipment and services as early and consistently as possible throughout their design...
-
4.1 Q. If an owner adds four or more dwelling units to an existing building, are those units covered by the Fair Housing Act?
A. Yes, provided that the units constitute a new addition to the building and not substantial rehabilitation of existing units.
-
9.1 Q. If a building was used previously for a nonresidential purpose, such as a warehouse, office building, or school, and is being converted to a multifamily dwelling, must the building meet the requirements of the Fair Housing Act?
A. No, the Fair Housing Act applies to covered multifamily dwellings for first occupancy after March 13, 1991, and the Fair Housing Act regulation defines first occupancy as a...
-
19.1 Q. If a sliding door track has a threshold of 3/4, does this trigger requirements for ramps?
A. No. The Guidelines at Requirement 4 provide that thresholds at doors, including sliding door tracks, may be no higher than 3/4 and must be beveled with a slope no greater than 1:2.
-
Section 2. Single-story dwelling unit
"Single-story dwelling unit" means a dwelling unit with all finished living space located on one floor.
-
§ 35.151(f)(1)
(1) Kitchens within housing units containing accessible sleeping rooms with mobility features (including suites and clustered sleeping rooms) or on floors containing accessible sleeping...
-
Fair Housing Act Design Manual
The manual was first published in August, 1996, and this update is intended to provide clear and helpful guidance about ways to design and construct housing which complies with the...
-
1133A.4.1, Item 2
2. Base cabinets directly under sinks and work surfaces shall be removable as required in Section 1133A.3.
- BORA Classic Cooktop Extraction System
- GE Profile™ Series 18" Built-In Dishwasher PDW1860NSS