When separate shower facilities are provided for men and women, at least one roll-in shower shall be provided for each group....
Search Results "Shower Slope"
Commonly Searched Documents
-
11B-224.8.2 More than 50-bed facilities
-
11B-608.5 Controls
Controls, faucets, and shower spray units shall comply with Section 11B-309.4 _|Operation|_. Controls and faucets shall be of a single-lever design. [2010 ADAS] 608.5 Controls. ...
-
11B-608.5 Controls
Controls, faucets, and shower spray units shall comply with Section 11B-309.4 _|Operation|_. Controls and faucets shall be of a single-lever design. [2010 ADAS] 608.5 Controls....
-
11B-406.5.8 Counter slope
Counter slopes of adjoining gutters and road surfaces immediately adjacent to and within 24 inches (610 mm) of the curb ramp shall not be steeper than 1:20....
-
11B-608.2.2.1 Clearance
A 36 inch (914 mm) wide minimum by 60 inch (1524 mm) long minimum clearance shall be provided adjacent to the open face of the shower compartment. [2010 ADAS] 608.2.2.1 Clearance. ...
-
5.3.2.3 Slope
The slope of the turning space and clear floor or ground space surface shall not be steeper than 1:48 (2 percent) in all directions....
-
Allowances for Typical Roadway Geometry
Allowances for Typical Roadway Geometry The 1991 ADAAG and 2004 ADA and ABA Accessibility Guidelines specify a maximum running slope of 5 percent and maximum cross slope of 2 percent...
-
7.4.5.2 Slope
The cross slope of a passing space shall not exceed 1:20 (5 percent) in any direction....
-
1c
Is there a 36" wide by 48" long clear floor space directly outside the shower for persons who use wheelchairs to approach and use the shower as shown in Figure 35(a) above?...
-
4.21.3 SEAT
A seat shall be provided in shower stalls 36 in by 36 in (915 mm by 915 mm) and shall be as shown in Fig. 36....
-
1d
Does the 36" x 48" clear floor space directly outside the shower extend at least 12" past the seat wall of the shower to allow for a seat-to-seat transfer from the wheelchair?...
-
4.8.1 General
Outdoor rinsing showers shall provide a hand-held shower spray unit complying with ABAAS section 608.6....
-
§ 35.151(e)(2)
(2) Facilities with more than 50 beds covered by this section that provide common use bathing facilities shall provide at least one roll-in shower with a seat that complies with the relevant...
-
11B-608.5 Controls
Controls, faucets, and shower spray units shall comply with Section 11B-309.4. Controls and faucets shall allow the user to close and open the water supply....
-
1134A.6 Showers
Showers required to be accessible shall comply with this section....
-
11B-1009.3 Sloped entries
Sloped entries shall comply with Section 11B-1009.3. [2010 ADAS] Advisory 1009.3 Sloped Entries. ...
-
11B-1009.3 Sloped entries
Sloped entries shall comply with Section 11B-1009.3. [2010 ADAS] Advisory 1009.3 Sloped Entries....
-
11B-1009.3 Sloped entries
Sloped entries shall comply with Section 11B-1009.3. Advisory 11B-1009.3 Sloped entries. Personal wheelchairs and mobility devices may not be appropriate for submerging in water....
-
11B-608.2.2.1 Clearance
A 36 inch (914 mm) wide minimum by 60 inch (1524 mm) long minimum clearance shall be provided adjacent to the open face of the shower compartment. [2010 ADAS] 608.2.2.1 Clearance....
-
11B-608.2.2.1 Clearance
A 36 inch (914 mm) wide minimum by 60 inch (1524 mm) long minimum clearance shall be provided adjacent to the open face of the shower compartment....
-
B2. Slope
Is the vehicle space relatively level (2% maximum slope in all directions)? Yes _____ No _____...
-
R304.3.2 Running Slope
R304.3.2 Running Slope. The running slope of the curb ramp shall be in-line with the direction of sidewalk travel....
-
11B-1009.3.3 Handrails
At least two handrails complying with Section 11B-505 shall be provided on the sloped entry....
-
608.2.3 Alternate Roll-In Type Shower Compartments
608.2.3 Alternate Roll-In Type Shower Compartments....