In buildings where a required accessible floor is four or more stories above or below a level of exit discharge, not less than one required accessible means of egress shall be an elevator...
Search Results "Secondary Accessible Means of Entry"
-
1009.2.1 Elevators required
-
1007.2.1 Elevators required
In buildings where a required accessible floor is four or more stories above or below a level of exit discharge, at least one required accessible means of egress shall be an elevator complying...
-
1007.6 Areas of refuge
Every required area of refuge shall be accessible from the space it serves by an accessible means of egress....
- AXS Map App - Find, Rate and Share Accessible Places
-
Submerged Depth
Submerged Depth Sloped entries must extend to a depth between 24 inches minimum and 30 inches maximum below the stationary water level....
-
1009.3.2 Submerged Depth
Sloped entries shall extend to a depth of 24 inches (610 mm) minimum and 30 inches (760 mm) maximum below the stationary water level....
-
11B-1009.3.2 Submerged depth
Sloped entries shall extend to a depth of 24 inches (610 mm) minimum and 30 inches (762 mm) maximum below the stationary water level....
-
1009.3.2 Submerged Depth
Sloped entries shall extend to a depth of 24 inches (610 mm) minimum and 30 inches (760 mm) maximum below the stationary water level....
-
F216.4.3 Directional Signs
Building Code (2000 edition) or section 1007.7 of the International Building Code (2003 edition) (incorporated by reference, see "Referenced Standards" in Chapter 1) to provide directions to accessible...
-
216.4.3 Directional Signs
Building Code (2000 edition) or section 1007.7 of the International Building Code (2003 edition) (incorporated by reference, see "Referenced Standards" in Chapter 1) to provide directions to accessible...
-
A4.1.3(9)
A4.1.3(9) Supervised automatic sprinkler systems have built in signals for monitoring features of the system such as the opening and closing of water control valves, the power...
-
1003.1 Applicability
The general requirements specified in Sections 1003 through 1013 shall apply to all three elements of the means of egress system, in addition to those specific requirements for the exit...
-
1003.1 Applicability
The general requirements specified in Sections 1003 through 1015 shall apply to all three elements of the means of egress system, in addition to those specific requirements for the exit...
-
1003.1 Applicability
The general requirements specified in Sections 1003 through 1015 shall apply to all three elements of the means of egress system, in addition to those specific requirements for the exit...
-
1009.3.2 Submerged Depth
Sloped entries shall extend to a depth of 24 inches (610 mm) minimum and 30 inches (760 mm) maximum below the stationary water level....
-
11B-1009.3.2 Submerged depth
Sloped entries shall extend to a depth of 24 inches (610 mm) minimum and 30 inches (762 mm) maximum below the stationary water level....
-
11B-1009.3.2 Submerged depth
Sloped entries shall extend to a depth of 24 inches (610 mm) minimum and 30 inches (762 mm) maximum below the stationary water level....
-
1132A.4.1 Thresholds
Thresholds at the primary entry and required exit doors shall be no higher than ½ inch (12.7 mm)....
-
Where can one get further information or technical assistance on the IBC, including its requirements for means of egress?
Technical assistance on the IBC is available from the International Code Council (ICC) at (888) ICC-SAFE (422-7233) or by email at CareCenter@iccsafe.org . For further information,...
-
11B-809.8 Doors
Primary entry doors, required exit doors, secondary exterior doors and interior doors shall comply with this section and Section 11B-809.8....
-
6d.
Does the lift allow a wheelchair user unassisted entry, operation, and exit? Yes _____ No _____...
-
1009.3.3 Handrails
At least two handrails complying with 505 shall be provided on the sloped entry....
-
Sec.36.308(a)(1)(ii)(C)
(C) Adjoin an accessible route that also serves as a means of egress in case of emergency; and...
-
f-iv
Does the lift allow a person using a mobility device unassisted entry, operation (is key available, if required), and exit? Yes No...