Where a site, building, facility, room, or space contains more than one use, each portion shall comply with the applicable requirements for that use....
Search Results "Plumbing Facility"
-
201.2 Application Based on Building or Facility Use
-
F208.2.2 Rehabilitation Facilities and Outpatient Physical Therapy Facilities
Twenty percent of patient and visitor parking spaces provided to serve rehabilitation facilities specializing in treating conditions that affect mobility and outpatient physical therapy...
-
208.2.2 Rehabilitation Facilities and Outpatient Physical Therapy Facilities
Twenty percent of patient and visitor parking spaces provided to serve rehabilitation facilities specializing in treating conditions that affect mobility and outpatient physical therapy...
-
1991 / 1994 ADA Standards - Plan Review Tool - Plumbing Fixtures
1991 / 1994 ADA Standards - Plan Review Tool - Plumbing Fixtures Click here to view/download the pdf "1991 / 1994 ADA Standards - Plan Review Tool - Plumbing Fixtures" (323 KB) * *...
-
11B-228.3.1.1 Existing facilities
Where new EVCS are added to a facility with existing EVCS, the requirements of Section 11B-812 shall apply only to the new EVCS installed....
-
11B-228.3.1.1 Existing facilities
Where new EVCS are added to a facility with existing EVCS, the requirements of Section 11B-812 shall apply only to the new EVCS installed....
-
BUILDING
The accessibility standards generally apply to buildings and facilities....
-
BUILDING
The accessibility standards generally apply to buildings and facilities....
-
810 Transportation Facilities
810 Transportation Facilities...
-
233 Residential Facilities
233 Residential Facilities...
-
Introduction of new § 35.152 for detention and correctional facilities. (Section-by-Section Analysis)
aging inmates who are not eligible for parole, the allegations in complaints received by the Department from inmates, and the Department's own experience with detention and correctional facilities...
-
11B-201.2 Application based on building or facility use
Where a site, building, facility, room, or space contains more than one use, each portion shall comply with the applicable requirements for that use. ...
-
11B-201.2 Application based on building or facility use
Where a site, building, facility, room, or space contains more than one use, each portion shall comply with the applicable requirements for that use....
-
11B-201.2 Application based on building or facility use
Where a site, building, facility, room, or space contains more than one use, each portion shall comply with the applicable requirements for that use....
-
11B-213.3.2 Water closets
Where water closets are provided, at least five percent but no fewer than one shall comply with Section 11B-604. ETA Editor's Note The 2013 CBC scoping for accessible water...
-
11B-608.2.3 Alternate roll-in type shower compartments
Alternate roll-in type shower compartments shall be 36 inches (914 mm) wide and 60 inches (1524 mm) deep minimum clear inside dimensions measured at center points of opposing sides....
-
608.2.3 Alternate Roll-In Type Shower Compartments
Alternate roll-in type shower compartments shall be 36 inches (915 mm) wide and 60 inches (1525 mm) deep minimum clear inside dimensions measured at center points of opposing sides....
-
Alternate Roll-in Showers
Comment. Specifications are provided for alternate roll-in showers, including their size and the location of entries (608.2.3). Comments indicated that this provision should be more...
-
608.2.3 Alternate Roll-In Type Shower Compartments
Alternate roll-in type shower compartments shall be 36 inches (915 mm) wide and 60 inches (1525 mm) deep minimum clear inside dimensions measured at center points of opposing sides....
-
608.2.3 Alternate Roll-In Type Shower Compartments
608.2.3 Alternate Roll-In Type Shower Compartments. Alternate roll-in type shower compartments shall be 36 inches (915 mm) wide and 60 inches (1525 mm) deep minimum clear inside...
-
4.24.2 Height
Sinks shall be mounted with the counter or rim no higher than 34 in (865 mm) above the finish floor.
-
Bathrooms
Bathrooms An accessible bathroom can be equipped with either a tub or shower (transfer or roll-in).
-
4.24.4 Depth
Each sink shall be a maximum of 6‒1/2 in (165 mm) deep.
-
4.24.4 DEPTH
Each sink shall be a maximum of 6-1/2 in (165 mm) deep.