Dirty hands don't mean kitchen fittings should be too. One touch with the back of your hand or wrist is all it takes to turn the faucet ON and OFF....
Search Results "Kitchen Counter"
- Grohe Minta Touch Pull-Down Kitchen Faucet with Touch Technology
-
7.3 CHECK-OUT AISLES
Clear aisle width shall comply with 4.2.1 and maximum adjoining counter height shall not exceed 36 in (915 mm) above the floor....
-
Partitions: ADA Standard Section 231.4.2
Section 231.4.2 covers scoping requirements in the current ADA Standards for partitions.
-
11B-231.4.2 Partitions
Where solid partitions or security glazing separate visitors from detainees at least one of each type of cubicle or counter partition shall comply with Section 11B-904.6....
-
11B-231.4.2 Partitions
Where solid partitions or security glazing separate visitors from detainees at least one of each type of cubicle or counter partition shall comply with Section 11B-904.6....
-
11B-804.6.3 Dishwasher
Clear floor or ground space shall be positioned adjacent to the dishwasher door. The dishwasher door, in the open position, shall not obstruct the clear floor or ground space for the...
-
11B-804.6.3 Dishwasher
Clear floor or ground space shall be positioned adjacent to the dishwasher door. The dishwasher door, in the open position, shall not obstruct the clear floor or ground space for the...
-
Dishwasher: ADA Standard Section 804.6.3
Clear floor or ground space shall be positioned adjacent to the dishwasher door. The dishwasher door, in the open position, shall not obstruct the clear floor or ground space for the...
- American Standard Jardin 1-Handle Pull-Out Kitchen Faucet 4184F
-
7(1)(c)
(c) In U-shaped kitchens with sink or range or cooktop at the base of the "U", a 60-inch turning radius is provided to allow parallel approach, or base cabinets are removable at that location...
-
1133A.2.1, Item 1
U-shaped kitchens, designed with parallel approach at a range or cooktop located at the base of the U, shall have a minimum clear width of at least 60 inches (1524 mm)....
-
1133A.2.1, Item 1
U-shaped kitchens, designed with parallel approach at a range or cooktop located at the base of the U, shall have a minimum clear width of at least 60 inches (1524 mm)....
-
804.5 Storage
At least 50 percent of shelf space in storage facilities shall comply with 811. [ECTCR UFAS 4.34.6.10(1)]
-
11B-804.6.5.2 Bottom-hinged door ovens
Bottom-hinged door ovens shall have the work surface required by Section 11B-804.3 positioned adjacent to one side of the door.
-
804.6.5.2 Bottom-Hinged Door Ovens
Bottom-hinged door ovens shall have the work surface required by 804.3 positioned adjacent to one side of the door.
-
804.6.5.1 Side-Hinged Door Ovens
Side-hinged door ovens shall have the work surface required by 804.3 positioned adjacent to the latch side of the oven door.
-
11B-804.5 Storage
At least 50 percent of shelf space in storage facilities shall comply with Section 11B-811.
-
11B-804.6.5.1 Side-hinged door ovens
Side-hinged door ovens shall have the work surface required by Section 11B-804.3 positioned adjacent to the latch side of the oven door.
-
A4.34.6.1 CLEARANCE
The minimum clearances provide satisfactory maneuvering spaces for wheelchairs only if cabinets are removed at the sink.
-
11B-804.5 Storage
At least 50 percent of shelf space in storage facilities shall comply with Section 11B-811.
-
11B-804.6.5.2 Bottom-hinged door ovens
Bottom-hinged door ovens shall have the work surface required by Section 11B-804.3 positioned adjacent to one side of the door.