Bottom-hinged door ovens shall have the work surface required by 804.3 positioned adjacent to one side of the door.
Search Results "Kitchen Clearance"
-
804.6.5.2 Bottom-Hinged Door Ovens
-
804.6.5.1 Side-Hinged Door Ovens
Side-hinged door ovens shall have the work surface required by 804.3 positioned adjacent to the latch side of the oven door.
-
804.6.5.1 Side-Hinged Door Ovens
Side-hinged door ovens shall have the work surface required by 804.3 positioned adjacent to the latch side of the oven door.
-
804.6.5.2 Bottom-Hinged Door Ovens
Bottom-hinged door ovens shall have the work surface required by 804.3 positioned adjacent to one side of the door.
-
804.5 Storage
At least 50 percent of shelf space in storage facilities shall comply with 811.
-
804.5 Storage
804.5 Storage. At least 50 percent of shelf space in storage facilities shall comply with 811.
-
11B-804.5 Storage
At least 50 percent of shelf space in storage facilities shall comply with Section 11B-811.
-
11B-804.6.5.1 Side-hinged door ovens
Side-hinged door ovens shall have the work surface required by Section 11B-804.3 positioned adjacent to the latch side of the oven door.
-
804.6.5.1 Side-Hinged Door Ovens
804.6.5.1 Side-Hinged Door Ovens. Side-hinged door ovens shall have the work surface required by 804.3 positioned adjacent to the latch side of the oven door.
-
804.6.5.2 Bottom-Hinged Door Ovens
804.6.5.2 Bottom-Hinged Door Ovens. Bottom-hinged door ovens shall have the work surface required by 804.3 positioned adjacent to one side of the door.
-
11B-804.5 Storage
At least 50 percent of shelf space in storage facilities shall comply with Section 11B-811.
-
11B-804.6.5.2 Bottom-hinged door ovens
Bottom-hinged door ovens shall have the work surface required by Section 11B-804.3 positioned adjacent to one side of the door.
-
11B-804.6.5.1 Side-hinged door ovens
Side-hinged door ovens shall have the work surface required by Section 11B-804.3 positioned adjacent to the latch side of the oven door.
-
11B-804.5 Storage
At least 50 percent of shelf space in storage facilities shall comply with Section 11B-811.
-
11B-804.6.5.2 Bottom-hinged door ovens
Bottom-hinged door ovens shall have the work surface required by Section 11B-804.3 positioned adjacent to one side of the door.
-
11B-804.6.5.1 Side-hinged door ovens
Side-hinged door ovens shall have the work surface required by Section 11B-804.3 positioned adjacent to the latch side of the oven door.
-
4.13.6 Maneuvering Clearances at Doors
Minimum maneuvering clearances at doors that are not automatic or power-assisted shall be as shown in Fig. 25....
-
4.34.2(13)
(13) The kitchen shall comply with 4.34.6....
-
1133A.6 Kitchen sink faucet controls
1133A.6 Kitchen sink faucet controls. ...
-
11B-804.1 General
Kitchens, kitchenettes, and wet bars shall comply with Section 11B-804....
-
11B-804.1 General
Kitchens, kitchenettes, and wet bars shall comply with Section 11B-804....
-
11B-804.1 General
Kitchens, kitchenettes, and wet bars shall comply with Section 11B-804....
-
11B-307.4 Vertical clearance
Vertical clearance shall be 80 inches (2032 mm) high minimum. Guardrails or other barriers shall be provided where the vertical clearance is less than 80 inches (2032 mm) high....
-
11B-307.4 Vertical clearance
Vertical clearance shall be 80 inches (2032 mm) high minimum. Guardrails or other barriers shall be provided where the vertical clearance is less than 80 inches (2032 mm) high....