At the top of a stair flight, handrails shall extend horizontally above the landing for 12 inches (305 mm) minimum beginning directly above the first riser nosing....
Search Results "Horizontal Dispersion"
-
11B-505.10.2 Top extension at stairs
-
11B-505.10.2 Top extension at stairs
At the top of a stair flight, handrails shall extend horizontally above the landing for 12 inches (305 mm) minimum beginning directly above the first riser nosing....
-
1134A.6, Item 5
When a threshold is used, it shall be a maximum of 2 inches (50.8 mm) in height and have a beveled or sloped angle not exceeding 1 unit vertical in 2 units horizontal (26.6 degrees from...
-
1134A.6, Item 5
When a threshold is used, it shall be a maximum of 2 inches (50.8 mm) in height and have a beveled or sloped angle not exceeding 1 unit vertical in 2 units horizontal (26.6 degrees from...
-
11B-809.10.6.5 Thresholds
Where provided thresholds shall be 2 inches (51 mm) maximum in height and have a beveled or sloped angle not exceeding 1 unit vertical in 2 units horizontal (26.6 degrees from the horizontal...
-
§ 36.406(f)(1)
(1) Wheelchair and companion seating locations are dispersed to all levels of the facility that are served by an accessible route;...
-
11B-223.1 General
The lack of a design requirement does not mean that covered entities are not required to provide services to people with disabilities where accessible rooms are not dispersed in specialty...
-
11B-223.1 General
The lack of a design requirement does not mean that covered entities are not required to provide services to people with disabilities where accessible rooms are not dispersed in specialty...
-
Re: American Specialties 9014 Surface Mounted Horizontal Baby Changing Station
Rejected this after installation. The design of the hand hold is completely sloped at about 45 degrees. My fingers slipped off unless I applied tremendous pinching force to operate....
-
Web Accessibility 101: Screen Magnification & Reflow in Acrobat Reader
Requires the Registered User plan or above. Login!
-
Top Extension at Stairs: ADA Standard Section 505.10.2
Section 505.10.2 covers the current ADA Standards for the handrail extensions at the top of the stairs.
-
§ 36.406(f)(1)
(1) In stadiums, arenas, and grandstands, wheelchair spaces and companion seats are dispersed to all levels that include seating served by an accessible route;...
-
11B-223.1 General
Because medical facilities frequently reconfigure spaces to reflect changes in medical specialties, Section 11B-223.1 does not include a provision for dispersion of accessible patient bedrooms...
-
ACCESSIBLE MEANS OF EGRESS
A continuous and unobstructed way of egress travel from any point in a building or facility that provides an accessible route to an area of refuge, a horizontal exit, or a public way....
-
ACCESSIBLE MEANS OF EGRESS
A continuous and unobstructed way of egress travel from any point in a building or facility that provides an accessible route to an area of refuge, a horizontal exit, or a public way....
-
221.6 Stadiums, Arenas, and Grandstands
Wheelchair spaces and companion seats shall be dispersed to all levels that include seating served by an accessible route....
-
Alterations: ADA Standard Section 223.1.1
Section 223.1.1 ADA Standards for alterations to medical care and long-term care facilities.
-
Transfer Supports: ADA Standard Section 1008.3.2.3
Some examples of supports include a rope loop, a loop type handle, a slot in the edge of a flat horizontal or vertical member, poles or bars, or D rings on the corner posts....
-
11B-1008.3.2.3 Transfer supports
Some examples of supports include a rope loop, a loop type handle, a slot in the edge of a flat horizontal or vertical member, poles or bars, or D rings on the corner posts. ◼...
-
11B-1008.3.2.3 Transfer supports
Some examples of supports include a rope loop, a loop type handle, a slot in the edge of a flat horizontal or vertical member, poles or bars, or D rings on the corner posts. ◼...
-
11B-411.2.1.4.1.1 Arrangement
Buttons shall be arranged in columns to the right of the keypad with a minimum horizontal spacing of 1.5 times the horizontal spacing between the numeric keys and with the same vertical...
-
11B-411.2.1.4.1.1 Arrangement
Buttons shall be arranged in columns to the right of the keypad with a minimum horizontal spacing of 1.5 times the horizontal spacing between the numeric keys and with the same vertical...
-
11B-411.2.1.4.1.1 Arrangement
Buttons shall be arranged in columns to the right of the keypad with a minimum horizontal spacing of 1.5 times the horizontal spacing between the numeric keys and with the same vertical...
-
Adjustable gap protocol
Adjustable gap protocol: From initial setup, just the horizontal distance between the WMD and platform was incrementally increased by placing plywood blocks of 3.5” (8.9cm) width between...