As the car passes a floor and when a car stops at a floor served by the elevator, the corresponding character shall illuminate. Exception: Reserved....
Search Results "Elevator Building"
-
11B-407.4.8.1.3 Floor arrival
-
11B-407.3.3 Reopening device
Elevator doors shall be provided with a reopening device complying with Section 11B-407.3.3 that shall stop and reopen a car door and hoistway door automatically if the door becomes obstructed...
-
Section I: Elevators
(§407.4.1) I3 Are hallway elevator call buttons 48" high or lower?...
-
11B-407.2.2.1 Visible and audible signals
In existing elevators, a signal indicating the direction of car travel shall not be required....
-
11B-407.2.2.1 Visible and audible signals
In existing elevators, a signal indicating the direction of car travel shall not be required....
-
Alterations to elevators. (Section-by-Section Analysis)
One commenter suggested that this requirement would be difficult for small businesses located in older buildings, and one commenter suggested that this requirement be sent back to the Access...
-
11B-407.4.7.2 Keypads
ETA Editor's Note The preceding CBC requirements for elevator controls at 11B-407.4.6 and 11B-407.4.7 are more stringent than those of 2010 ADA Standards....
-
11B-407.4.7.2 Keypads
ETA Editor's Note The preceding CBC requirements for elevator controls at 11B-407.4.6 and 11B-407.4.7 are more stringent than those of 2010 ADA Standards....
-
Elevator Exemption
The 500 square foot maximum was based on a floor area allowance of 100 square feet per occupant, which is consistent with model building code requirements for business and industrial occupancies...
-
F233.4.4.1 Alterations to Vacated Buildings
Where a building is vacated for the purposes of alteration and the altered building contains more than 15 residential dwelling units, at least 5 percent of the residential dwelling units...
-
11B-411.2.1.7.4 Adjacency assignment
The system shall assign an elevator car immediately to the left or right of the hall call console....
-
11B-411.2.1.7.4 Adjacency assignment
The system shall assign an elevator car immediately to the left or right of the hall call console....
-
2. Section-by-Section Analysis of Final Guidelines
The following presents a section-by-section analysis of the final Guidelines. The text of the final Guidelines is organized into five sections. The first four sections of the...
-
Section 2: Accessibility Guidelines.
The issues addressed in this section concern the technical specifications set forth in the Fair Housing Accessibility Guidelines.
-
Section 5. Guidelines
[See subsections ...]
-
11B-407.4.6.1 Location
Exceptions: Where the elevator panel serves more than 16 openings and a parallel approach is provided, buttons with floor designations shall be permitted to be 54 inches (1372 mm)...
-
11B-407.4.6.1 Location
Exceptions: Where the elevator panel serves more than 16 openings and a parallel approach is provided, buttons with floor designations shall be permitted to be 54 inches (1372 mm)...
-
407.2 Elevator Landing Requirements
407.2 Elevator Landing Requirements. Elevator landings shall comply with 407.2....
-
§100.205(e)(2)(vi) 2006 International Building Code
(vi) 2006 International Building Code; published by ICC, January 2006, with the January 31, 2007, erratum to correct the text missing from Section 1107.7.5, if adopted without modification...
-
III-7.5115 Elevators and platform lifts
III−7.5115 Elevators and platform lifts (ADAAG §4.1.3(5))....
-
11B-408.4.1 Car dimensions and doors
Elevator cars shall provide a clear width 42 inches (1067 mm) minimum and a clear depth 54 inches (1372 mm) minimum....
-
11B-408.4.1 Car dimensions and doors
Elevator cars shall provide a clear width 42 inches (1067 mm) minimum and a clear depth 54 inches (1372 mm) minimum....
-
11B-407.4.10 Support rail
Support rails in elevator cabs are used in a different way than handrails along a walking surface such as a ramp or stairway....
-
11B-407.4.10 Support rail
Support rails in elevator cabs are used in a different way than handrails along a walking surface such as a ramp or stairway....