Section 608.7 covers the current ADA Standards for thresholds in shower compartments.
Search Results "Curb Line"
Commonly Searched Documents
-
Thresholds: ADA Standard Section 608.7
-
Floor or Ground Surfaces: ADA Standard Section 405.4
Section 405.4 covers the current ADA Standards for the floor or ground surfaces of ramps.
-
Cross Slope: ADA Standard Section 405.3
Section 405.3 covers the current ADA Standards for cross slope requirements on ramps.
-
9.a [§ 4.7.5]
To measure the slope of a curb ramp’s flared side, place a level on the flared side near the edge of the curb. The level should be placed so that it is parallel to the curb....
-
1.9.1.1.5
1.9.1.1.5 With respect to buildings, structures, sidewalks, curbs and related facilities not requiring a building permit, building standards published in the California Building Standards...
-
1.9.1.1.4
1.9.1.1.4 With respect to buildings, structures, sidewalks, curbs and related facilities not requiring a building permit, building standards published in the California Building Standards...
-
11B-705.1.2.2.2.1 One entrance/exit point
Where the turning space has one entrance/exit point other than the sloped ramp segments, detectable warnings shall be 36 inches (914 mm) deep, as measured perpendicular to the curb, and...
-
Components: ADA Standard Section 402.2
Section 402.2 covers the current ADA Standards for components of an accessible routes.
-
5. Curb ramps
Curb ramps 4.7 Accessible routes crossing curbs....
-
R304.2.2 Running Slope
The running slope of the curb ramp shall cut through or shall be built up to the curb at right angles or shall meet the gutter grade break at right angles where the curb is curved....
-
11B-402.2 Components
Accessible routes shall consist of one or more of the following components: walking surfaces with a running slope not steeper than 1:20, doorways, ramps, curb ramps excluding the flared...
- Figure 406.4 Landings at the Top of Curb Ramps – Drawing from the U.S. Access Board
-
11B-303.5 Warning curbs
changes in level exceeding 4 inches (102 mm) in a vertical dimension between walks, sidewalks or other pedestrian ways and adjacent surfaces or features shall be identified by warning curbs...
-
6.10
and §§ 221 and 802 of the ADA and ABA Accessibility Guidelines for Buildings and Facilities, as published in the Federal Register on July 23, 2004, to (a) provide wheelchair spaces with lines...
-
11B-303.5 Warning curbs
changes in level exceeding 4 inches (102 mm) in a vertical dimension between walks, sidewalks or other pedestrian ways and adjacent surfaces or features shall be identified by warning curbs...
-
11B-303.5 Warning curbs
changes in level exceeding 4 inches (102 mm) in a vertical dimension between walks, sidewalks or other pedestrian ways and adjacent surfaces or features shall be identified by warning curbs...
-
DSA Drawing 11B-406-8 Parallel Curb Ramp with No Gutter (2016 CBC)
Requires the Premium User plan or above. (Login or upgrade your account!)
- Show us your #CrappyCurb
-
G. What are Detectable Warnings, Why are They Required, and Where Must They be Provided?
The ADA Standards require that curb ramps include features called “detectable warnings.”...
-
DSA Drawing 11B-406-5C Curb Ramp Adjoining a Parking Access Aisle next to a Curb and Gutter (2016 CBC)
Requires the Premium User plan or above. (Login or upgrade your account!)
-
DSA Drawing 11B-406-6 Perpendicular Curb Ramp with No Gutter (2016 CBC)
Requires the Premium User plan or above. (Login or upgrade your account!)
-
11B-812.5.3 Relationship to accessible routes
A curb, wheel stop, bollards, or other barrier shall be provided if required to prevent encroachment of vehicles over the required clear width of adjacent accessible routes....
-
4.7.4 Surface
Surfaces of curb ramps shall comply with 4.5....