In a wheelchair accessible compartment with an in-swinging door, a minimum 60 inches (1524 mm) wide by 36 inches (914 mm) deep maneuvering space shall be provided in front of the clearance...
Search Results "Compartment Depth"
-
11B-604.8.1.1.1 Maneuvering space with in-swinging door
-
11B-809.10.6.5 Thresholds
Where provided thresholds shall be 2 inches (51 mm) maximum in height and have a beveled or sloped angle not exceeding 1 unit vertical in 2 units horizontal (26.6 degrees from the...
-
11B-809.10.6.5 Thresholds
Where provided thresholds shall be 2 inches (51 mm) maximum in height and have a beveled or sloped angle not exceeding 1 unit vertical in 2 units horizontal (26.6 degrees from the...
-
Side Approach
In June 1993, additional specifications were provided for the maximum height based on the reach depth....
-
308 Reach Ranges
Accessible reach ranges are specified according to the approach (forward or side) and the depth of reach over any obstruction....
-
604.8.1.6 Lavatory
In new construction, the wheelchair accessible toilet compartment shall contain an accessible lavatory within it, which must be at least 19 inches wide by 17 inches deep, nominal size, and...
-
Wall Depth and Length: ADA Standard Section 1009.4.3
The depth of the transfer wall shall be 12 inches (305 mm) minimum and 16 inches (405 mm) maximum....
- Boost Your Business - Chapter 10 - Restroom Fixtures
-
11B-308.3.1 Unobstructed
Exceptions: An obstruction shall be permitted between the clear floor or ground space and the element where the depth of the obstruction is 10 inches (254 mm) maximum....
-
Depth: ADA Standard Section 703.2.1
Raised characters shall be 1/32 inch (0.8 mm) minimum above their background.
-
Depth: ADA Standard Section 802.1.3
Where a wheelchair space can be entered from the front or rear, the wheelchair space shall be 48 inches (1220 mm) deep minimum. Where a wheelchair space can be entered only from the...
-
308.3.1 Unobstructed
An obstruction shall be permitted between the clear floor or ground space and the element where the depth of the obstruction is 10 inches (255 mm) maximum. 2....
-
308.3.1 Unobstructed
An obstruction shall be permitted between the clear floor or ground space and the element where the depth of the obstruction is 10 inches (255 mm) maximum. 2....
-
11B-308.3.1 Unobstructed
An obstruction shall be permitted between the clear floor or ground space and the element where the depth of the obstruction is 10 inches (254 mm) maximum. 2. ...
-
308.3.1 Unobstructed
An obstruction shall be permitted between the clear floor or ground space and the element where the depth of the obstruction is 10 inches (255 mm) maximum. 2....
- Figure 604.8.1.2 Wheelchair Accessible Toilet Compartment Doors – Drawing from the U.S. Access Board
-
308.3.1 Unobstructed
An obstruction shall be permitted between the clear floor or ground space and the element where the depth of the obstruction is 10 inches (255 mm) maximum. 2....
-
11B-308.3.1 Unobstructed
An obstruction shall be permitted between the clear floor or ground space and the element where the depth of the obstruction is 10 inches (254 mm) maximum. 2. ...
-
Size and Arrangement [4.17.3]
[See subsections ...]
-
Bathrooms
Bathrooms An accessible bathroom can be equipped with either a tub or shower (transfer or roll-in).
-
11B-604.8.1.1.2 Maneuvering space with side-opening door
In a wheelchair accessible compartment with a door located in the side wall or partition, either in-swinging or out-swinging, a minimum 60 inches (1524 mm) wide and 60 inches (1524 mm) deep...
-
4.23.4 Water Closets
If toilet stalls are provided, then at least one shall be a standard toilet stall complying with 4.17; where 6 or more stalls are provided, in addition to the stall complying with...
-
604.8.1.7 Water closet
In new construction, the accessible water closet within the wheelchair accessible compartment shall be located in the corner, diagonal to the door....
-
11B-604.8.1.1.2 Maneuvering space with side-opening door
In a wheelchair accessible compartment with a door located in the side wall or partition, either in-swinging or out-swinging, a minimum 60 inches (1524 mm) wide and 60 inches (1524 mm) deep...