Search Results "Clear Space"
- Figure 604.3.1 Size of Clearance at Water Closets – Drawing from the U.S. Access Board
- Figure 1009.4.3 Depth and Length of Tranfer Walls – Drawing from the U.S. Access Board
-
11B-806.2.3.1 Personal lift device floor space
There shall be a clear space under the bed for the use of a personal lift device....
-
4.16.2 Clear Floor Space
Clear floor space for water closets not in stalls shall comply with Fig. 28. Clear floor space may be arranged to allow either a left-handed or right-handed approach....
-
11B-813.2.10 Door swing
A door, in any position, shall be permitted to encroach into the turning space by 12 inches (305 mm) maximum....
-
11B-612.2 Bench
Doors shall not swing into the clear floor space required by Section 11B-903.2....
-
11B-612.2 Bench
Doors shall not swing into the clear floor space required by Section 11B-903.2....
-
11B-813.2.10 Door swing
A door, in any position, shall be permitted to encroach into the turning space by 12 inches (305 mm) maximum....
-
1133A.2 Clear floor space
Clear floor space at kitchens shall comply with the following:...
-
Turning Space [§304]
Turning Space [§304] Turning space is required in these accessible rooms and spaces: toilet and bathing facilities dressing, fitting, and locker rooms transient...
-
Refrigerator/Freezer: ADA Standard Section 804.6.6
Combination refrigerators and freezers shall have at least 50 percent of the freezer space 54 inches (1370 mm) maximum above the finish floor or ground....
-
11B-804.6.6 Refrigerator/freezer
Combination refrigerators and freezers shall have at least 50 percent of the freezer space 54 inches (1372 mm) maximum above the finish floor or ground....
-
11B-804.6.6 Refrigerator/freezer
Combination refrigerators and freezers shall have at least 50 percent of the freezer space 54 inches (1372 mm) maximum above the finish floor or ground....
-
Beds: ADA Standard Section 807.2.3
Where beds are provided, clear floor space complying with 305 shall be provided on at least one side of the bed....
-
11B-807.2.3 Beds
Where beds are provided, clear floor space complying with Section 11B-305 shall be provided on at least one side of the bed....
-
11B-807.2.3 Beds
Where beds are provided, clear floor space complying with Section 11B-305 shall be provided on at least one side of the bed....
-
5.3.2.1 Size
The clear floor or ground space shall be 60 inches (1525 mm) wide minimum measured parallel with the back of the pit toilet, and 56 inches (1420 mm) deep minimum measured parallel to the...
- Neo-Metro Urinal Divider Number 8949-N
-
4.1.1 General
In alterations, where a condition for exception in section 1.1 prohibits full compliance with a specific requirement for clear floor or ground space surface slope, size, or location, the...
- Landscape Forms Inc. Parc Vue Trash Receptacle
-
11B-804.3.1 Clear floor or ground space
A clear floor space complying with Section 11B-305 positioned for a forward approach shall be provided....
-
11B-804.3.1 Clear floor or ground space
A clear floor space complying with Section 11B-305 positioned for a forward approach shall be provided....
-
11B-804.3.1 Clear floor or ground space
A clear floor space complying with Section 11B-305 positioned for a forward approach shall be provided....