Doors cannot swing into required clear floor or ground spaces in these specific instances: clear floor space at controls for automatic and power assisted doors and gates (404.3.5...
Search Results "Clear"
-
Can doors swing into required clear floor or ground space?
-
R404.1 General
Clear spaces shall comply with R404. Advisory R404.1 General....
-
11B-605.3 Clear floor space
A clear floor or ground space complying with Section 11B-305 positioned for forward approach shall be provided....
-
11B-605.3 Clear floor space
A clear floor or ground space complying with Section 11B-305 positioned for forward approach shall be provided....
-
1009.4.1 Clear Deck Space
A clear deck space of 60 inches (1525 mm) minimum by 60 inches (1525 mm) minimum with a slope not steeper than 1:48 shall be provided at the base of the transfer wall....
-
Water Closet Clear Floor Space
The proposed rule stated that no fixtures (other than the water closet) or obstructions were to be located within the clear floor space (604.3.1)....
-
Clear Floor Space [4.19.3]
Clear Floor Space [4.19.3] Clear floor space should be centered at the fixture (although this is not specifically required by ADAAG)....
-
903.2 Clear Floor or Ground Space
Clear floor or ground space complying with 305 shall be provided and shall be positioned at the end of the bench seat and parallel to the short axis of the bench....
-
4.2.4.2 RELATIONSHIP OF MANEUVERING CLEARANCE TO WHEELCHAIR SPACES
One full unobstructed side of the clear floor or ground space for a wheelchair shall adjoin or overlap an accessible route or adjoin another wheelchair clear floor space....
-
11B-1008.4.2 Clear floor or ground space
Clear floor or ground space complying with Sections 11B-305.2 and 11B-305.3 shall be provided at play components. [2010 ADAS] Advisory 1008.4.2 Clear Floor or Ground Space....
-
11B-1008.4.2 Clear floor or ground space
Clear floor or ground space complying with Sections 11B-305.2 and 11B-305.3 shall be provided at play components. Advisory 11B-1008.4.2 Clear floor or ground space....
-
Installation: ADA Standard Section 609.7
Section 609.7 covers the current ADA Standards for the installations of grab bars.
-
11B-609.7 Installation
Grab bars shall be installed in any manner that provides a gripping surface at the specified locations and that does not obstruct the required clear floor space....
-
11B-609.7 Installation
Grab bars shall be installed in any manner that provides a gripping surface at the specified locations and that does not obstruct the required clear floor space....
-
11B-707.2 Clear floor or ground space
A clear floor or ground space complying with Section 11B-305 shall be provided....
-
11B-707.2 Clear floor or ground space
A clear floor or ground space complying with Section 11B-305 shall be provided....
-
4.7.6 Water Hydrant Clear Floor or Ground Space
Clear floor or ground space around a water hydrant shall be 48 inches (1220 mm) by 72 inches (1830 mm) with the long side of the space adjoining an outdoor recreation access route, trail...
-
6. Clear floor space
Clear floor space: Adequate space is provided to approach the toilet from a variety of wheelchair transfer positions (i.e. diagonal or side approaches)....
-
7.4.11.1 Clear Space
Trailhead signs shall be located centered at the back of a 30- by 48-inch (760- by 1,220-millimeter) minimum clear floor or ground space....
-
1002.6.1 Clear Floor or Ground Space
A clear floor or ground space complying with 305 shall be provided in the load and unload area adjacent to the transfer device....
-
1002.6.1 Clear Floor or Ground Space
A clear floor or ground space complying with 305 shall be provided in the load and unload area adjacent to the transfer device....
-
Appropriate clear floor space
Appropriate clear floor space (shown by dashed lines) is needed adjacent to each cell feature (see page 1 diagrams on clear floor space)....
-
4.2.4.2 Relationship of Maneuvering Clearance to Wheelchair Spaces
One full unobstructed side of the clear floor or ground space for a wheelchair shall adjoin or overlap an accessible route or adjoin another wheelchair clear floor space....
-
305.6 Approach
One full unobstructed side of the clear floor or ground space shall adjoin an accessible route or adjoin another clear floor or ground space....