404.2 Manual Doors, Doorways, and Manual Gates. Manual doors and doorways and manual gates intended for user passage shall comply with 404.2....
Search Results "Alternate Door"
-
404.2 Manual Doors, Doorways, and Manual Gates
-
Specifications for Alternate Roll-in Shower Controls
Specifications for controls, faucets, and shower spray units for alternate roll-in showers are provided in section 608.5.3....
-
11B-404.2.6 Doors in series and gates in series
The distance between two hinged or pivoted doors in series and gates in series shall be 48 inches (1219 mm) minimum plus the width of doors or gates swinging into the space....
-
11B-404.2.6 Doors in series and gates in series
The distance between two hinged or pivoted doors in series and gates in series shall be 48 inches (1219 mm) minimum plus the width of doors or gates swinging into the space....
-
Shower and Sauna Doors in Transient Lodging Facilities
Shower and Sauna Doors in Transient Lodging Facilities....
-
III-4.3600 Limitations and alternatives
III−4.3600 Limitations and alternatives....
-
Door Maneuvering Clearance
Table 404.2.4.1 specifies maneuvering clearances for manual swinging doors and gates....
-
224.1.2 Guest Room Doors and Doorways
224.1.2 Guest Room Doors and Doorways....
-
11B-407.3.3.1 Height
The device shall be activated by sensing an obstruction passing through the opening at 5 inches (127 mm) nominal and 29 inches (737 mm) nominal above the finish floor.
-
11B-407.3.3.1 Height
The device shall be activated by sensing an obstruction passing through the opening at 5 inches (127 mm) nominal and 29 inches (737 mm) nominal above the finish floor.
-
Height: ADA Standard Section 407.3.3.1
Section 407.3.3.1 covers the current ADA Standards for the height requirements of an elevators reopening device.
-
382.10 How does a U.S. or foreign carrier obtain a determination that it is providing an equivalent alternative to passengers with disabilities?
Alternatives that provide less accessibility than the provisions of the rule, or that impose greater burdens on passengers with disabilities, cannot be considered an equivalent alternatives...
-
F224.1.2 Guest Room Doors and Doorways
Advisory F224.1.2 Guest Room Doors and Doorways....
-
224.1.2 Guest Room Doors and Doorways
Advisory 224.1.2 Guest Room Doors and Doorways....
-
404.2.2 Double-Leaf Doors and Gates
At least one of the active leaves of doorways with two leaves shall comply with 404.2.3 and 404.2.4.
-
404.2.2 Double-Leaf Doors and Gates
At least one of the active leaves of doorways with two leaves shall comply with 404.2.3 and 404.2.4.
-
Section 36.305 Alternatives to Barrier Removal (Preamble, Section-by-Section Analysis)
Similarly, if it is not readily achievable to ramp a long flight of stairs leading to the front door of a restaurant or a pharmacy, the restaurant or the pharmacy must take alternative measures...
-
Maneuvering Space at Doors
Several commenters requested that the final Guidelines incorporate minimum maneuvering clearances at doors, as provided by the ANSI Standard....
-
11B-307.4 Vertical clearance
Exception: Door closers and door stops shall be permitted to be 78 inches (1981 mm) minimum above the finish floor or ground. ...
-
11B-307.4 Vertical clearance
Exception: Door closers and door stops shall be permitted to be 78 inches (1981 mm) minimum above the finish floor or ground. ...
-
Vertical Clearance: ADA Standard Section 307.4
Section 307.4 covers the current ADA Standards for vertical clearance.
-
1132A.3 Width and height of interior doors and secondary exterior doors
Doors shall comply with the following:...
-
11B-404.2.4.3 Recessed doors and gates
, measured perpendicular to the face of the door or gate...
-
404.2 Manual Doors, Doorways, and Manual Gates
Manual doors and doorways and manual gates intended for user passage shall comply with 404.2....