Contrast in percent shall be determined by: Contrast percent = [(B1-B2)/B1] x 100 percent where B1 = light reflectance value (LRV) of the lighter area and B2 = light reflectance...
Search Results "Viewing Area"
-
11B-705.1.1.3.2
-
11B-1002.4.3 Gaps
Floors of amusement rides with wheelchair spaces and floors of load and unload areas shall be coordinated so that, when amusement rides are at rest in the load and unload position, the vertical...
-
III. DISCUSSION
altered area are readily accessible to and usable by individuals with disabilities, including individuals who use wheelchairs, upon completion of the alterations....
-
11B-804.2.2 U-Shaped
In U-shaped kitchens enclosed on three contiguous sides, clearance between all opposing base cabinets, counter tops, appliances, or walls within kitchen work areas shall be 60 inches (1524...
-
11B-203.14 Raised diving boards and diving platforms
accessible route complying with Division 4 shall be provided to the ground- or floor-level entry points, where provided, of stairs, ladders, or other means of reaching the raised elements or areas...
-
1002 Amusement Rides
This section also addresses access at loading and unloading areas and provides criteria for wheelchair spaces, ride seats designed for transfer, and transfer devices....
-
505.3 Continuity
EXCEPTION: In assembly areas, handrails on ramps shall not be required to be continuous in aisles serving seating....
-
Maps/floor plans
at the front desk for use during the Museum visit an up-to-date tactile map of the Museum's current floor plan, including temporary exhibitions, changes to the permanent exhibition and areas...
-
11B-608.6 Shower spray unit and water
Corrects prior drafting error by limiting the types of facilities that are allowed to use the vandalism prone area exception and requiring one of the two shower heads to be a maximum of...
-
§ 37.42(e)(2)
mini-high platform or where the physical structure of an existing station does not allow such clearance), barriers must be used to prevent the flow of pedestrian traffic through these narrower areas...
-
505.3 Continuity
EXCEPTION: In assembly areas, handrails on ramps shall not be required to be continuous in aisles serving seating....
-
230 Two-Way Communication Systems
Where a two-way communication system is provided to gain admittance to a building or facility or to restricted areas within a building or facility, the system shall comply with 708....
-
F245.4.4 Location
This section requires outdoor recreation access routes to coincide with or be located in the same general area as general circulation paths....
-
F244.5.4 Location
This section requires outdoor recreation access routes to coincide with or be located in the same general area as general circulation paths....
-
Is there a limit on the total length (number of runs) a ramp may have?
(Ramps in play areas are limited to a 12” max. rise)....
-
11B-203.14 Raised diving boards and diving platforms
accessible route complying with Division 4 shall be provided to the ground- or floor-level entry points, where provided, of stairs, ladders, or other means of reaching the raised elements or areas...
-
§ 37.42(e)(2)
mini-high platform or where the physical structure of an existing station does not allow such clearance), barriers must be used to prevent the flow of pedestrian traffic through these narrower areas...
-
§ 38.23(c)(7) Stowage
A compartment, securement system, or other appropriate method shall be provided to ensure that stowed ramps, including portable ramps stowed in the passenger area, do not impinge on a passenger's...
-
§ 38.159(c)(7) Stowage
A compartment, securement system, or other appropriate method shall be provided to ensure that stowed ramps, including portable ramps stowed in the passenger area, do not impinge on a passenger's...
-
11B-203.14 Raised diving boards and diving platforms
accessible route complying with Division 4 shall be provided to the ground- or floor-level entry points, where provided, of stairs, ladders, or other means of reaching the raised elements or areas...
-
11B-804.2.2 U-Shaped
In U-shaped kitchens enclosed on three contiguous sides, clearance between all opposing base cabinets, counter tops, appliances, or walls within kitchen work areas shall be 60 inches (1524...
-
505.3 Continuity
EXCEPTION: In assembly areas, handrails on ramps shall not be required to be continuous in aisles serving seating....
-
EXTREME WALKS
Requires the Registered User plan or above. Login!
-
11B-502.3.3 Marking
The area within the blue borderlines shall be marked with hatched lines a maximum of 36 inches (914 mm) on center in a color contrasting with that of the aisle surface, preferably blue or...