Signs required by Chapter 10, Section 1009.9 at doors to areas of refuge and exterior areas for assisted rescue shall comply with Sections 11B-703.1, 11B-703.2, 11B-703.3, and 11B-703.5...
Search Results "Door Maneuvering Clearance"
Commonly Searched Documents
-
11B-216.4.2 Areas of refuge and exterior areas for assisted rescue
-
Developing a plan based on priorities
Priority 1: Getting through the Door The first priority is to make sure individuals with disabilities can physically enter the facility as independently as possible....
-
D5. Raised Threshold
If there is a raised threshold, is it no higher than 3/4 inch at the door and beveled on both sides?...
-
Picnic Tables
All new picnic table installations must comply with requirements for accessible seating spaces, table clearance, slope, and surface....
-
Re: Co-sharing of Accessible Parking access Aisles by adjacent elevator door allowed?
Pedestrians in the elevator would be stepping directly into a vehicular way upon exiting the elevator cab. How would you address the requirement for detectable warnings? Changes in...
-
1009.4.1 Clear Deck Space
Where two grab bars are provided, the clear deck space shall be centered on the clearance between the grab bars. Figure 1009.4.1 Clear Deck Space at Transfer Walls...
-
11B-806.2.3.1 Personal lift device floor space
ETA Editor's Note The clearance prescribed for a personal lift device at 2013 CBC 11B-806.2.3.1 is not required by 2010 ADAS....
-
Is there a minimum distance between changes in level?
Ramps and curb ramps, which must be used to span vertical changes greater than ½”, must have level landings and clearances at the tops and bottoms of each run to provide adequate separation...
-
Protrusion Limits [§307.2]
Those with leading edges that are within cane sweep (27” high maximum) or that provide minimum headroom clearance (80” minimum) do not pose hazards and can protrude any amount....
-
§ 38.23(a) General
., lift or ramp) complying with paragraph (b) or (c) of this section and sufficient clearances to permit a wheelchair or other mobility aid user to reach a securement location....
-
11B-806.2.3.1 Personal lift device floor space
ETA Editor's Note The clearance prescribed for a personal lift device at CBC 11B-806.2.3.1 is not required by 2010 ADAS....
-
11B-806.2.3.1 Personal lift device floor space
ETA Editor's Note The clearance prescribed for a personal lift device at CBC 11B-806.2.3.1 is not required by 2010 ADA Standards....
- State of California Disability Access Services (DAS) - Boost Your Business: Physical Access, Technical Assistance & CASp
-
g-v
If the answers to questions g-ii thru g-iv are No, can the door be propped open? ...
-
11B-245.3 Accessible elements required
The accessible portion of the residence extends to those elements used to enter the commercial facility, including the front sidewalk, if any, the door or entryway, and hallways; and those...
-
11B-245.3 Accessible elements required
The accessible portion of the residence extends to those elements used to enter the public accommodation, including the front sidewalk, if any, the door or entryway, and hallways; and those...
-
11B-245.3 Accessible elements required
The accessible portion of the residence extends to those elements used to enter the commercial facility, including the front sidewalk, if any, the door or entryway, and hallways; and those...
-
502.2.1 On-street parallel parking
Curbs adjacent to such spaces must be of a height that does not interfere with the opening and closing of motor vehicle doors. Figure 502.2 Vehicle Parking Spaces...
-
4.3.3 Width
The minimum clear width of an accessible route shall be 36 in (915 mm) except at doors (see 4.13.5 and 4.13.6)....
-
II. Rulemaking History
maximum running slope of vehicle ramps to 1:8 (as compared to the existing guidelines, which specify a range of ramp slopes from 1:4 to 1:12, depending on deployment), require additional maneuvering...
- Inclusion Solutions Voting Booth Accessories Franklin Voting Chair
-
Housekeeping
Reminder: Do not place any tables, furniture, or other items on the pull-side of the door to the room, which could prevent a person from opening/closing the door. (18 inches clear required...
-
11B-705.2 Detectable directional texture
This surface will be placed directly behind the yellow detectable warning texture specified in Section 11B-705.1.2.1, aligning with all doors of the transit vehicles where passengers will...