6. ...are the other exterior ramps at least 36" wide (between handrails)? [ADA Stds. 4.8.3] Yes __ No __ N/A __ Comments: _________________________________________
Search Results "Clear Deck Space"
-
6. Exterior Ramp Clear Width between Handrails
-
1009.4.2 Height
The height of the transfer wall shall be 16 inches (405 mm) minimum and 19 inches (485 mm) maximum measured from the deck. Figure 1009.4.2 Transfer Wall Height...
-
212 and 606 Kitchens, Kitchenettes, Lavatories, and Sinks
The technical requirements address clear floor space, height, faucets, and exposed pipes and surfaces....
-
7b.
[ADA Stds 4.13.9] Yes _____ No _____ A clear floor space on the latch side of the door (pull side) allows a person using a wheelchair or scooter to pull the door open and then...
-
Doors and Gates in Series [§404.2.6]
Doors and Gates in Series [§404.2.6] At hinged or pivoted doors or gates in series, a separation is required that is at least 48” plus the width of doors or gates swinging into the space...
-
409.3.2 Location
Elevator car doors or gates shall be positioned at the narrow end of the clear floor spaces required by 409.4.1....
-
409.3.2 Location
Elevator car doors or gates shall be positioned at the narrow end of the clear floor spaces required by 409.4.1....
-
11B-1009.2.4 Seat
The height of the lift seat shall be designed to allow a stop at 17 inches (432 mm) minimum to 19 inches (483 mm) maximum measured from the deck to the top of the seat surface when in the...
-
11B-1009.2.4 Seat
The height of the lift seat shall be designed to allow a stop at 17 inches (432 mm) minimum to 19 inches (483 mm) maximum measured from the deck to the top of the seat surface when in the...
-
11B-1009.4.2 Height
The height of the transfer wall shall be 16 inches (406 mm) minimum and 19 inches (483 mm) maximum measured from the deck. FIGURE 11B-1009.4.2 TRANSFER WALL HEIGHT...
-
Do the Standards specify a maximum travel distance between parking spaces and facility entrances?
The Standards require that accessible parking spaces be on the shortest accessible route to an accessible entrance, but they do not specify a maximum travel distance, nor do they require...
-
605 Urinals
Section 604.5 provides criteria for accessible urinals, including the height and depth, clear floor space, and flush controls....
-
4.34.6.5(6)
(6) Counter thickness and supporting structure shall be 2 in (50 mm) maximum over the required clear space....
-
B4
For van-accessible spaces (particularly in a garage or parking structure), is there vertical clearance of at least 98 inches (8 feet - 2 inches) for the vehicle route to the parking space...
-
1134A.8, Item 4.3
Doors to the cabinet beneath the lavatory shall be removable or openable to provide the required unobstructed knee and toe space....
-
Side Approach
Side Approach Where space is provided for a side approach, controls can be mounted at the heights allowed for side reaches....
-
1134A.8, Item 4.3
Doors to the cabinet beneath the lavatory shall be removable or openable to provide the required unobstructed knee and toe space....
-
1009.4.2 Height
The height of the transfer wall shall be 16 inches (405 mm) minimum and 19 inches (485 mm) maximum measured from the deck. Figure 1009.4.2 Transfer Wall Height...
- Ohio Gratings Informational Video
-
4.4.1 General
In alterations, where a condition for exception in section 1.1 prohibits full compliance with a specific requirement for clear floor or ground space surface, slope, size, or location, the...
-
11B-1008.2.3 Water play components
Exceptions: Where the surface of the accessible route, clear floor or ground spaces, or turning spaces serving water play components is submerged, compliance with Sections 11B-302,...
-
11B-1008.2.3 Water play components
Exceptions: Where the surface of the accessible route, clear floor or ground spaces, or turning spaces serving water play components is submerged, compliance with Sections 11B-302,...
-
Weather Shelters
Weather Shelters Course weather shelters must be designed and constructed to allow a golf car to enter and exit, and have a clear floor or ground space of 60 inches by 96 inches minimum...
-
1015.6 Slope
This section requires the slope of the surface of the clear ground space and turning space to not be steeper than 1:48 in any direction....