Visible signal fixtures shall be centered at 72 inches (1829 mm) minimum above the finish floor or ground....
Search Results "Ground Surface"
Commonly Searched Documents
-
11B-407.2.2.2 Visible signals
-
11B-1008.2.5.2 Elevated
ETA Editor's Note The above restrictions on ramp slope for ramps connecting ground level play components, and on ramp rise for ramps connecting elevated play components, are more stringent...
-
§ 38.23(b)(8) Platform entrance ramp
The entrance ramp, or loading-edge barrier used as a ramp, shall not exceed a slope of 1:8, measured on level ground, for a maximum rise of 3 inches, and the transition from roadway or sidewalk...
-
11B-1008.2.5.2 Elevated
ETA Editor's Note The above restrictions on ramp slope for ramps connecting ground level play components, and on ramp rise for ramps connecting elevated play components, are more stringent...
-
11B-407.2.2.2 Visible signals
Visible signal fixtures shall be centered at 72 inches (1829 mm) minimum above the finish floor or ground....
- Spectrum Aquatics Summit 500BP Therapy Pool Lift (Battery Powered)
-
404.2.7 Door and Gate Hardware
Operable parts of such hardware shall be 34 inches (865 mm) minimum and 48 inches (1220 mm) maximum above the finish floor or ground....
-
404.2.7 Door and Gate Hardware
Operable parts of such hardware shall be 34 inches (865 mm) minimum and 48 inches (1220 mm) maximum above the finish floor or ground....
-
404.2.7 Door and Gate Hardware
Operable parts of such hardware shall be 34 inches (865 mm) minimum and 48 inches (1220 mm) maximum above the finish floor or ground....
-
1007.2 Accessible Routes
Accessible routes located on playing surfaces of miniature golf holes shall be permitted to use the exceptions in 1007.2. EXCEPTIONS: 1....
-
1007.2 Accessible Routes
Accessible routes located on playing surfaces of miniature golf holes shall be permitted to use the exceptions in 1007.2. EXCEPTIONS: 1....
-
6.1 Deliberative Process
At its first meeting, the Advisory Committee considered this NPRM recommendation of 17” to 19”, which applied to either fixed or adjustable height transfer surfaces....
-
Thresholds at Exterior Doors/Thresholds to Balconies or Decks
A number of commenters from the building industry objected to the provision of the Option One guidelines that specified that an exterior deck, balcony, patio, or similar surface may be no...
-
Appendix B Trails Study Participation Press Release
Appendix B Trails Study Participation Press Release National Center on Accessibility National Trails Surface Study Press Release NCA Seeks Land Managers with Trails to Participate...
-
11B-1005.3.1 Curb or barrier
Curbs or barriers shall extend 2 inches (51 mm) minimum above the surface of the fishing pier or platform....
-
1005.3.1 Curb or Barrier
Curbs or barriers shall extend 2 inches (51 mm) minimum above the surface of the fishing pier or platform....
-
505 Handrails
505 Handrails The 2010 Standards add a new technical requirement at section 406.3 for handrails along walking surfaces....
-
1005.3.1 Curb or Barrier
Curbs or barriers shall extend 2 inches (51 mm) minimum above the surface of the fishing pier or platform....
-
d-iv
Are the handrails mounted 34 to 38 inches above the ramp surface? [ADA Standards § 4.8.5] Yes No...
-
f-vii
Are the handrails mounted 34 to 38 inches above the ramp surface? [ADA Standards § 4.8.5] Yes No...
-
6f. Ramp Handrails
Are the handrails mounted between 34 and 38 inches above the ramp surface? [ADA Stds 4.8.5] Yes _____ No _____...
-
4c.
Are the handrails mounted between 34 and 38 inches above the ramp surface? [ADA Stds 4.8.5] Yes _____ No _____...
-
11B-1005.3.1 Curb or barrier
Curbs or barriers shall extend 2 inches (51 mm) minimum above the surface of the fishing pier or platform....
-
11B-1005.3.1 Curb or barrier
Curbs or barriers shall extend 2 inches (51 mm) minimum above the surface of the fishing pier or platform....