ASTM F 1292-99 and ASTM F 1292-04 establish a uniform means to measure and compare characteristics of surfacing materials to determine whether materials provide a safe surface under and...
Search Results "End Transfer Surface"
-
[2010 ADAS] 105.2.3 ASTM
-
406.2 Counter Slope
Counter slopes of adjoining gutters and road surfaces immediately adjacent to the curb ramp shall not be steeper than 1:20....
-
Clear floor space beside or between beds must be 36" wide
Remember that because the clear floor space required by 806.2.3 will be deeper than 24" to end up beside or between the beds where it will be usable, it will be in an alcove that is at least...
-
707.6.3.1 Contrast
Function keys shall contrast visually from background surfaces. Characters and symbols on key surfaces shall contrast visually from key surfaces....
-
707.6.3.1 Contrast
Function keys shall contrast visually from background surfaces. Characters and symbols on key surfaces shall contrast visually from key surfaces....
-
A4.30.8 Illumination Levels
Illumination levels on the sign surface shall be in the 100 to 300 lux range (10 to 30 footcandles) and shall be uniform over the sign surface....
-
Forward Approach: ADA Standard Section 904.4.2
A portion of the counter surface that is 30 inches (760 mm) long minimum and 36 inches (915 mm) high maximum shall be provided....
-
Top Extension at Stairs: ADA Standard Section 505.10.2
Section 505.10.2 covers the current ADA Standards for the handrail extensions at the top of the stairs.
-
11B-406.5.8 Counter slope
Counter slopes of adjoining gutters and road surfaces immediately adjacent to and within 24 inches (610 mm) of the curb ramp shall not be steeper than 1:20....
- Accessible Mats for Beach and Outdoor Events
-
Obstacles [1016.5]
Obstacles are anything that interrupts the evenness of the surface of an ORAR....
-
R302.7.1 Vertical Alignment
Where pedestrian access routes cross rails at grade, the pedestrian access route surface shall be level and flush with the top of rail at the outer edges of the rails, and the surface between...
-
ADOPTION OF A 19 INCH HEIGHT MINIMIZES COSTS TO HEALTH CARE PROVIDERS
ADOPTION OF A 19 INCH HEIGHT MINIMIZES COSTS TO HEALTH CARE PROVIDERS In the absence of Committee consensus commending a departure from the existing broadly accepted transfer surface...
-
3.2 MDE Advisory Committee Process
In all cases except one – the minimum height of transfer surfaces – the Committee reached consensus on the recommended accessibility standards (see Section 5)....
-
1.4 Overview of Report
Section 6 briefly introduces the standard about which Committee members did not reach consensus: the minimum transfer surface height....
-
410.6 Doors and Gates
End doors and gates shall provide a clear width 32 inches (815 mm) minimum. Side doors and gates shall provide a clear width 42 inches (1065 mm) minimum....
-
11B-410.6 Doors and gates
End doors and gates shall provide a clear width 32 inches (813 mm) minimum. Side doors and gates shall provide a clear width 42 inches (1067 mm) minimum....
-
610.3.2 L-Shaped Seats
The end of the "L" shall be 22 inches (560 mm) minimum and 23 inches maximum (585 mm) from the main seat wall....
-
11B-604.5.1 Side wall
wall grab bar shall be 42 inches (1067 mm) long minimum, located 12 inches (305 mm) maximum from the rear wall and extending 54 inches (1372 mm) minimum from the rear wall with the front end...
-
R208.2 Where Not Required
Detectable warning surfaces are not required at pedestrian refuge islands that are cut-through at street level and are less than 1.8 meters (6.0 ft) in length in the direction of pedestrian...
-
Summary of Results
Therefore, the results can be addressed in terms of a general trend in types of surface materials used....
-
Section 1193.23 Product design, development and evaluation
At this end of the evaluation spectrum, only one hour of professional time is projected to be required, for an estimated cost of $80....
-
Plan 4B: 13-Foot Wide Accessible Guest Room
section 806); • Alternate roll-in type shower with folding seat is 36 inches deep and 60 inches wide (section 608.2.3); • Alternate roll-in shower has a 36-inch wide entry at one end...
-
4.Information, documentation, and training
Such information and documentation includes user guides, installation guides for end-user installable devices, and product support communications, regarding both the product in general and...