The accessibility function button shall be located directly below the keypad at a height of 36 inches (914 mm) to 42 inches (1067 mm) above the finish floor....
Search Results "Alternate Pedestrian Access Route"
-
11B-411.2.1.3.1 Keypad call console arrangement
-
11B-411.2.1.3.1 Keypad call console arrangement
The accessibility function button shall be located directly below the keypad at a height of 36 inches (914 mm) to 42 inches (1067 mm) above the finish floor....
-
11B-411.2.1.3.1 Keypad call console arrangement
The accessibility function button shall be located directly below the keypad at a height of 36 inches (914 mm) to 42 inches (1067 mm) above the finish floor....
-
Deaf or Hard of Hearing
building egress system, like a fire alarm horn or voice instructions, then that person has a hearing impairment that could affect his or her ability to evacuate in an emergency unless alternatives...
-
11B-604.8.1.1.2 Maneuvering space with side-opening door
In a wheelchair accessible compartment with a door located in the side wall or partition, either in-swinging or out-swinging, a minimum 60 inches (1524 mm) wide and 60 inches (1524 mm) deep...
-
Question 10
Is the accessible entrance into the building free of obstacles that block the clear wall and floor space needed for opening the door (between 18 and 42 inches on the latch side of the door...
-
Section A: Parking
access aisle?...
-
4. Applicability
Applicability The SNPRM: We proposed to apply the WCAG 2.0 Web site accessibility standard to U.S. and foreign carrier primary Web sites that market (i.e., advertise or sell) air transportation...
-
Accessible Routes from Site Arrival Points [§206.2.1]
Accessible Routes from Site Arrival Points [§206.2.1]...
-
11B-604.8.1.1.2 Maneuvering space with side-opening door
In a wheelchair accessible compartment with a door located in the side wall or partition, either in-swinging or out-swinging, a minimum 60 inches (1524 mm) wide and 60 inches (1524 mm) deep...
-
1009.8 Two-way communication
A two-way communication system complying with Sections 1009.8.1 and 1009.8.2 shall be provided at the landing serving each elevator or bank of elevators on each accessible floor that is...
-
11B-604.2 Location
maximum from the side wall or partition, except that the water closet shall be 17 inches (432 mm) minimum and 19 inches (483 mm) maximum from the side wall or partition in the ambulatory accessible...
-
11B-604.8.1.1.2 Maneuvering space with side-opening door
In a wheelchair accessible compartment with a door located in the side wall or partition, either in-swinging or out-swinging, a minimum 60 inches (1524 mm) wide and 60 inches (1524 mm) deep...
-
§ 36.302(f)(1) General
A public accommodation shall modify its policies, practices, or procedures to ensure that individuals with disabilities can purchase tickets for accessible seating during the same hours,...
-
11B-604.2 Location
maximum from the side wall or partition, except that the water closet shall be 17 inches (432 mm) minimum and 19 inches (483 mm) maximum from the side wall or partition in the ambulatory accessible...
-
11B-604.2 Location
maximum from the side wall or partition, except that the water closet shall be 17 inches (432 mm) minimum and 19 inches (483 mm) maximum from the side wall or partition in the ambulatory accessible...
- Door King Inc. 1802 and 1802-EPD Electronic Programmable Directory Telephone Entry System
-
11B-411.2.1.2 Required features
Hall call consoles shall include a touch screen or keypad with display screen, an accessibility function button, and audio output loudspeaker....
-
11B-411.2.1.2 Required features
Hall call consoles shall include a touch screen or keypad with display screen, an accessibility function button, and audio output loudspeaker....
-
Basic Components for Accessible and Usable Public and Common Use Areas or Facilities
[See subsections ...]
- The HSC Health Care System