Verge image gallery Available in Evero Natural Quartz Surface Evero Natural Quartz Materials are now GREENGUARD Certified as low-emitting materials TAS compliant...
Search Results "Abrasive Surface"
Commonly Searched Documents
- Bradley 3 Station Verge Lavatory System LVRD3
 - Gamco 1.5 Inch Diameter Straight Grab Bar with Snap Flange - 150S Series-Snap
 - 
    
  
  11B-406.5.3 Landings
  
The landing provides an area for users to exit the curb ramp and proceed along the walking surface at the top of the curb ramp....
 - 
    
  
  Toilet Paper Dispensers
  
This may effectively preclude some dispensers from being located above grab bars in view of the minimum mounting height of grab bars (33 inches, measured to the top of the gripping surface...
 - 
    
  
  Issue 5: Tactile arrow (in line)
  
Figure 13: APS installed on poles in the landscape strip, and still within reach from a level paved sidewalk surface....
 - 
    
  
  Q2.)  What are the types of “field conditions” that were anticipated where the advisory says “tolerances recognized by this provision include those for field conditions”?
  
And a concrete finisher clearly cannot guarantee that the slope of a concrete curb ramp will be consistently 8.33% across its entire surface. ...
 - 
    
  
  606.2 Clear Floor Space
  
clearance of 24 inches (610 mm) minimum above the finish floor or ground shall be permitted at lavatories and sinks used primarily by children 6 through 12 years where the rim or counter surface...
 - 
    
  
  Ground-Level Accessible Routes
  
At ground level, objects may not protrude into the 60-inch wide space of an accessible route up to or below the height of 80 inches (2030 mm), measured above the accessible route surface...
 - 
    
  
  5. Conflicts Between Shared Path Users
  
The comments also recommended design solutions to avoid conflicts between users, including separate pathways for pedestrians and bicyclists; and detectable warning surfaces at intersections...
 - 
    
  
  b. Positioning Supports
  
Section-by-Section Analysis – M305.2), the MDE Advisory Committee made recommendations to add requirements for positioning supports on mammography equipment and imaging equipment with transfer surfaces...
 - 
    
  
  606.2 Clear Floor Space
  
clearance of 24 inches (610 mm) minimum above the finish floor or ground shall be permitted at lavatories and sinks used primarily by children 6 through 12 years where the rim or counter surface...
 - 
    
  
  Existing Trails [F247.2]
  
the trail; clearing the trail of encroaching brush or grasses; and removing rock slides Maintaining trail tread, such as filling ruts, reshaping a trail bed, repairing a trail surface...
 - 
    
  
  Medical Diagnostic Equipment Accessibility Standards Sub-Committee Recommendations Weight Scales
  
Types Of Equipment To Which Technical Criteria Applies Seated in a wheelchair (M303) Wheelchair space, including orientation, width, depth, knee and toe clearance, and surface...
 - 
    
  
  R209 Accessible Pedestrian Signals and Pedestrian Pushbuttons (Section-by-Section Analysis)
  
., audible tones and vibrotactile surfaces) to pedestrians who are blind or have low vision....
 - 
    
  
  R410.6 Character Height
  
Table R410.6 Visual Character Height Height to Finish Surface from Baseline of Character Horizontal Viewing Distance Minimum Character Height 1.0 m (3.3...
 - 
    
  
  "Other Power-Driven Mobility Device" (Section-by-Section Analysis)
  
designed for areas or conditions without defined pedestrian areas, such as off-road bike paths, roads (except where allowed by law or where a sidewalk is not provided), freeways, or natural surfaces...
 - 
    
  
  606.2 Clear Floor Space
  
clearance of 24 inches (610 mm) minimum above the finish floor or ground shall be permitted at lavatories and sinks used primarily by children 6 through 12 years where the rim or counter surface...
 - 
    
  
  Protruding Objects and Trails
  
such as signs that extend into the clear width area of a trail, resting interval, or passing space between 27 inches (685 millimeters) and 80 inches (2,030 millimeters) above the travel surface...
 - 
    
  
  Trail Facilities
  
not accessible— must be designed to comply with the applicable provisions in FSORAG, except that slopes not steeper than 1:20 (5 percent) are allowed if necessary for drainage of unpaved surfaces...
 - 
    
  
  1018.1 General
  
The technical requirements address connections (1018.2); surface (1018.3); clear width (1018.4); obstacles (1018.5); openings (1018.6); slopes, including running slope (1018.7.1) and cross...
 - 
    
  
  Developing a plan based on priorities
  
In order to promote safety, a portable ramp should be properly secured; have railings; and a firm, stable, nonslip surface....
 - 
    
  
  Waviness Index
  
The Waviness Index measures the bumps and dips in a floor surface as the average of deviations up or down from the mid - points of 2 - , 4 - , 6 - , 8 - , and 10 - foot chords....
 - 
    
  
  Positioning Supports Considered
  
., length, height above the patient support surface, location) to ensure their effectiveness?...
 - 
    
  
  Protruding Objects
  
Requirements: All objects that protrude from surfaces or posts and all overhanging objects in areas where people walk shall comply with the following requirements: Objects mounted...