While first responders do their best to get to a site and the particular location of those needing their assistance, there is no way to predict how long any given area will remain a safe...
Search Results "Signage Location"
Commonly Searched Documents
-
What Assistance Will the Person(s) Provide?
-
Is Identification of Which Means of Egress Are Available/Closest Necessary?
Simple floor plans of the building indicating the location of and routes to usable circulation paths should be available in alternative formats such as single-line, high-contrast plans....
-
Clear Width [1016.3]
ORARs may be different widths, depending on their location....
-
Width of Spaces [1012.2]
Utility hookups for RVs are typically located on the driver’s side of the vehicle....
-
Small governmental jurisdictions affected by proposed accessibility guidelines
Many of these small governmental jurisdictions are located in rural areas, which generally do not construct pedestrian transportation networks (e.g., sidewalks, pedestrian street crossings...
-
233.3.4 Alterations
considered in comparing one dwelling unit to another should include the number of bedrooms; amenities provided within the dwelling unit; types of common spaces provided within the facility; and location...
-
R306.3 Roundabouts
Pedestrian street crossings at roundabouts can be difficult for pedestrians who are blind or have low vision to identify because the crossings are located off to the side of the pedestrian...
-
Alternative text is needed for images, links, controls and form elements
To locate guidance on alternate text for links, controls and form elements, see Agency-specific information at the back of this document....
-
Toilet Compartments
Toilet Compartments Baby changing tables are not prohibited from being located in wheelchair accessible toilet compartments; however, the minimum space required by TAS 604.8.1.1 for...
-
20.1 Q. If a covered multifamily dwelling has an individual, private garage which is attached to and serves only that dwelling, does the garage have to be accessible in terms of width and length?
Question 14(c) addresses parking garages where there are several garages or stalls located together, either in a separate, detached building, or in a central area of the building, such as...
-
Proposed requirement for cell alterations. (Section-by-Section Analysis)
., cells other than those where alterations are originally planned), provided that: Each substitute cell is located within the same facility; is integrated with other cells to the maximum...
-
Section 5 Guidelines
doors usable by a person in a wheelchair, (4) accessible route into and through the covered dwelling unit; (5) light switches, electrical outlets and environmental controls in accessible locations...
-
233.3.4 Alterations
considered in comparing one dwelling unit to another should include the number of bedrooms; amenities provided within the dwelling unit; types of common spaces provided within the facility; and location...
-
12181(9) Readily achievable
facility; (C) the overall financial resources of the covered entity; the overall size of the business of a covered entity with respect to the number of its employees; the number, type, and location...
-
11B-502.5 Vertical clearance
Signs provided at entrances to parking facilities informing drivers of clearances and the location of van accessible parking spaces can provide useful customer assistance....
-
Grab Bars [4.16.4]
In existing facilities where the location of the flush valve conflicts with the grab bar, the bar can be split or shifted to the wide side....
-
4.7.10 Diagonal Curb Ramps
If diagonal curb ramps have flared sides, they shall also have at least a 24 in (610 mm) long segment of straight curb located on each side of the curb ramp and within the marked crossing...
-
Destination-Oriented Elevators
Destination-oriented elevators are different from typical elevators in that they provide a means of indicating the desired floor at the location of the call button, usually through a key...
-
Doorways [4.8.4]
Consider allowing additional space beyond the minimum maneuvering clearance required at doors and/or locating stair openings away from the accessible route connecting doors and ramps....
-
Forward Reach [4.2.5]
To be within easy reach, faucets and the operable portions of soap or towel dispensers should be located within, not beyond, the clear floor space....
-
Access to Performing Areas [4.33.5]
While handrails are not required on ramps adjacent to assembly seating, locating aisles (including those that are stepped) along walls will permit handrails on one side for the benefit of...
-
Mirrors [4.19.6]
Clear floor space (30 by 48 inches minimum) for a forward approach located outside the swing of doors should be provided at full-length mirrors....
-
2. a. ii. Responsibility
Responsibility Both the proprietor who owns the building where the facility is located and the tenant who owns or operates the facility are responsible for compliance with Title...