more than 24 inches (610 mm), beyond the vertical reference plane, the height of the operable part shall be 46 inches (1170 mm) high maximum and 15 inches (380 mm) high minimum above the floor...
Search Results "Floor Button"
-
407.12.2.2 Obstructed Side Reach
-
M301.4.2 Clearance Around Base
The base of the equipment shall provide a clearance 6 inches (150 mm) high minimum measured from the floor and 36 inches (915 mm) deep minimum measured from the edge of the examination surface...
-
M302.4.2 Clearance Around Base
The base of the equipment shall provide a clearance 6 inches (150 mm) high minimum measured from the floor and 36 inches (915 mm) deep minimum measured from the edge of the examination surface...
-
§ 38.113(d)(1) Requirements
with the boarding platform or mini-high platform design such that the horizontal gap between a car at rest and the platform shall be no greater than 3 inches and the height of the car floor...
-
1130A.1 General
The accessible route shall pass through the primary entry door, and shall connect with all additional exterior doors, required clear floor spaces at kitchen appliances and bathroom fixtures...
-
11B-604.7.1 Dispensers
The outlet of the dispenser shall be below the grab bar, 19 inches (483 mm) minimum above the finish floor and shall not be located behind grab bars....
-
1133A.3 Removable base cabinets
The finish floor beneath kitchen sinks and work surfaces shall be extended to the wall....
-
11B-233.3.1.2.4 Multi-story residential dwelling units in buildings with one or more elevators
multi-story residential dwelling units shall comply with the following: The primary entry of the multi-story residential dwelling unit shall be on an accessible route on the floor...
-
1133A.3 Removable base cabinets
The finish floor beneath kitchen sinks and work surfaces shall be extended to the wall....
-
11B-604.7.1 Dispensers
The outlet of the dispenser shall be below the grab bar, 19 inches (483 mm) minimum above the finish floor and shall not be located behind grab bars....
-
11B-809.9.3 Removable base cabinets
sinks and work surfaces provided that all of the following conditions are met: a) base cabinets can be removed without the use of specialized tools or knowledge; b) the finish floor...
-
1130A.1 General
The accessible route shall pass through the primary entry door, and shall connect with all additional exterior doors, required clear floor spaces at kitchen appliances and bathroom fixtures...
- Wingits Reversible L-shaped 26" x 22.5" Shower Seat
- Hamilton CapTel Apps for Smartphones
-
11B-202.4 Path of travel requirements in alterations, additions and structural repairs
Adding raised markings on elevator control buttons. Installing flashing alarm lights. Widening doors. Installing offset hinges to widen doorways....
-
11B-202.4 Path of travel requirements in alterations, additions and structural repairs
Adding raised markings on elevator control buttons. Installing flashing alarm lights. Widening doors. Installing offset hinges to widen doorways....
- BTX Intelligent Fashion Test For Drapery Track, 40Kg Load
- Spectrum Industries Inc. Freedom One Sit-to-Stand Lectern
- Part 11- Access Methods - Switch Access and Scanning
- Unity Surfacing Systems Soft-Land Rubberized Safety Surfacing
-
1130A.1 General
The accessible route shall pass through the primary entry door, and shall connect with all additional exterior doors, required clear floor spaces at kitchen appliances and bathroom fixtures...
-
ACCESSIBLE ROUTE
Interior accessible routes may include corridors, hallways, floors, ramps, elevators and lifts....
-
608.7 Thresholds
maximum shall be permitted in transfer type shower compartments in existing facilities where provision of a ½ inch (13 mm) high threshold would disturb the structural reinforcement of the floor...
-
604.9.6 Dispensers
The outlet of the dispenser shall be 14 inches (355 mm) minimum and 19 inches (485 mm) maximum above the finish floor....