(i) The type, size, weight, dimensions, and speed of the device;...
Search Results "Door Signal Device"
Commonly Searched Documents
-
§ 35.137(b)(2)(i)
-
§ 37.42(c)(3)
(3) Bridge plates, ramps or other appropriate devices;...
-
11B-707.6 Input
Input devices shall comply with Section 11B-707.6....
-
11B-411.3.3.2 Contact
The device contact shall comply with Section 11B-407.3.3.2....
-
7.4 Legal and Regulatory Considerations
has been changed in a way that could significantly affect the device’s safety or effectiveness....
-
Wheeled Mobility Anthropometry Project
There have been dramatic changes in mobility devices and the characteristics of people who use these devices....
-
4.3.11.1(5)
) A portion of a stairway landing within an exit enclosure which is vented to the exterior and is separated from the interior of the building with not less than one-hour fire-resistive doors...
-
4.30.6 MOUNTING LOCATION AND HEIGHT
Interior signage shall be located alongside the door on the latch side and shall be mounted at a height of between 54 in and 66 in (1370 mm and 1675 mm) above the finished floor....
-
§ 38.31(a)
(a) Any stepwell or doorway immediately adjacent to the driver shall have, when the door is open, at least 2 foot-candles of illumination measured on the step tread or lift platform....
-
§382.157(c)
., food allergies, chemical sensitivity), paraplegic, quadriplegic, other wheelchair, oxygen, stretcher, other assistive device (cane, respirator, etc.), and other disability....
-
1009.3 Sloped Entries
Personal wheelchairs and mobility devices may not be appropriate for submerging in water....
-
5.8.1.2.3 Double Ramped Entry - Edge Protection on the Platform sides Recommendations
Rationale for the recommendation Edge protection provides an additional safety feature and guides users of wheeled mobility devices on the platform....
-
1009.3 Sloped Entries
Personal wheelchairs and mobility devices may not be appropriate for submerging in water....
-
Human Subject Testing
Subjects were recruited by gender and mobility limitation (no known disability, ambulatory with limited mobility, ambulatory with assistive devices, and manual wheelchair use)....
-
Small entities potentially affected by proposed standards
The proposed standards do not impose any mandatory requirements on health care providers or medical device manufacturers....
-
11B-903.6 Structural strength
Allowable stresses shall not be exceeded for materials used when a vertical or horizontal force of 250 pounds (1112 N) is applied at any point on the seat, fastener, mounting device, or...
-
Locating Controls & Devices: Percent of People Who Can Reach the Matrix Cell Indicated While Holding No Weight - Forward Approach Manual Wheelchair
These data depict the reaching abilities of manual chair users represented as the percentage of users expected to reach to a target location in the forward reach direction for a...
-
Locating Controls & Devices: Percent of People Who Can Reach the Matrix Cell Indicated While Holding No Weight - Side Approach Power Chair
These data depict the reaching abilities of power chair users represented as the percentage of users expected to reach to a target location in the lateral or sideways reach...
-
Locating Controls & Devices: Percent of People Who Can Reach the Matrix Cell Indicated While Holding No Weight - Forward Approach Power Chair
These data depict the reaching abilities of power chair users represented as the percentage of users expected to reach to a target location in the forward reach direction for a...
-
Locating Controls & Devices: Percent of People Who Can Reach the Matrix Cell Indicated While Holding No Weight - Side Approach Manual Wheelchair
These data depict the reaching abilities of manual chair users represented as the percentage of users expected to reach to a target location in the lateral or sideways reach...
-
Section H: Lifts
(§§410.5, 309.4) H6 Is the clear width of the door opening/gate opening at the end of the lift at least 32"?...
-
106 Definitions
The following definitions have been removed as unnecessary, in most cases due to changes in certain scoping or technical requirements: "accessible route," "area of refuge," "automatic door...
-
General [9.1.1]
Where room numbers are provided, they must be raised and Brailled and located on the wall at the latch-sides of doors for safety and uniformity....
-
11B-604.3.2 Overlap
When the door to the toilet room is placed directly in front of the water closet, the water closet cannot overlap the required maneuvering clearance for the door inside the room. ◼ ...