Where one grab bar is provided, clearance shall be 24 inches (610 mm) minimum on both sides of the grab bar....
Search Results "Door Maneuvering Clearance"
-
1009.4.5 Grab Bars
-
11B-1009.4.5 Grab bars
Where one grab bar is provided, clearance shall be 24 inches (610 mm) minimum on both sides of the grab bar....
-
Fixed Seating and Tables
At least 27 inches of knee clearance must be provided between the floor and the underside of the table....
-
M305.3 Standing Supports (Section-by-Section Analysis)
in the MDE NPRM preamble on whether the cross section dimensions for gripping surfaces should be applied to standing supports and whether standing supports can provide a 1½ inch minimum clearance...
-
11B-805.6 Hand washing fixtures, lavatories and sinks
Knee clearance requirement - All accessibility requirements of Section 11B-606 apply to lavatories, sinks and handwashing fixtures required to be accessible. ...
-
11B-213.2.1 Unisex (single-user or family) toilet and unisex (single-user or family) bathing rooms
Doors to unisex (single-user or family) toilet rooms and unisex bathing rooms shall have privacy latches....
-
11B-216.8.3 Signs at toilet and urinal compartments
Exception: A sign with tactile characters shall be permitted on an in-swinging and self-closing door at compartments not required to comply with Section 11B-604 or Section 11B-605.5....
-
11B-216.8.3 Signs at toilet and urinal compartments
Exception: A sign with tactile characters shall be permitted on an in-swinging and self-closing door at compartments not required to comply with Section 11B-604 or Section 11B-605.5....
-
11B-213.2.1 Unisex (single-user or family) toilet and unisex (single-user or family) bathing rooms
Doors to unisex (single-user or family) toilet rooms and unisex bathing rooms shall have privacy latches....
-
Accessible Room Set-Up
., wheelchairs, scooters, walkers, crutches, canes) can maneuver throughout and use the amenities independently; people who are blind or have low vision can navigate easily and safely; people...
-
Ceiling Mounted Lifts
These lifts require no extra maneuvering space in the room adjacent to the exam table and require little storage space....
-
604.3.1 Size
Clearance around a water closet shall be 60 inches (1525 mm) minimum measured perpendicular from the side wall and 56 inches (1420 mm) minimum measured perpendicular from the rear wall....
-
306.3.1 General
Space under an element between 9 inches (230 mm) and 27 inches (685 mm) above the finish floor or ground shall be considered knee clearance and shall comply with 306.3....
-
604.3.1 Size
Clearance around a water closet shall be 60 inches (1525 mm) minimum measured perpendicular from the side wall and 56 inches (1420 mm) minimum measured perpendicular from the rear wall....
-
Signage
If Braille and raised letter signs are mounted on doors instead of walls, blind persons and persons with low vision may be hurt by someone who is pushing a door open while they are trying...
-
8.2 READING AND STUDY AREAS
Clearances between fixed accessible tables and study carrels shall comply with 4.3....
-
1008.1.9.7, Item 5
A sign shall be provided on the door located above and within 12 inches (305 mm) of the release device reading: “KEEP PUSHING....
-
A4.34.6.7 OVENS
Countertop or wall-mounted ovens with side-opening doors are easier for people in wheelchairs to use....
- Door King Inc. 1837 PC Programmable Telephone Entry and Access Control System
- Jacknob Corp. 9099 ADA Latch & Keeper Surface-Mounted Partition Door Hardware
-
I. Parking Garage
Does the parking garage serving the lodging facility allow at least 98" of vertical clearance for vehicles with raised roofs to approach, use and exit the accessible parking spaces?...
-
8.2 Reading and Study Areas
Clearances between fixed accessible tables and between study carrels shall comply with 4.3....
-
Kitchen Appliances
In the addition, the Board has added exceptions for appliance doors and door latching devices in section 804.6.2. Comment....
-
Transfer Entry
For those reasons, the opening provided to transfer from a wheelchair or mobility device must provide sufficient clearance for transfer....