This video is part of a longer animation produced by the U.S. Access Board. View the animation video in it's entirety on the Access Board's website here:...
Search Results "Shower Clear Floor Space"
Commonly Searched Documents
- Access Board: Accessible Parking Spaces and Access Aisles
-
4.3.2(3)
(3) At least one accessible route shall connect accessible building or facility entrances with all accessible spaces and elements and with all accessible dwelling units within the building...
-
11B-812.6.1 Van accessible
Vehicle spaces serving van accessible EVCS shall be 144 inches (3658 mm) wide minimum and shall have an adjacent access aisle complying with Section 11B-812.7....
-
11B-812.6.2 Standard accessible
Vehicle spaces serving standard accessible EVCS shall be 108 inches (2743 mm) wide minimum and shall have an adjacent access aisle complying with Section 11B-812.7....
-
11B-812.6.1 Van accessible
Vehicle spaces serving van accessible EVCS shall be 144 inches (3658 mm) wide minimum and shall have an adjacent access aisle complying with Section 11B-812.7....
-
11B-812.6.2 Standard accessible
Vehicle spaces serving standard accessible EVCS shall be 108 inches (2743 mm) wide minimum and shall have an adjacent access aisle complying with Section 11B-812.7....
- Access Board: Accessible Route Openings
-
407.2.3.2 Car Designations
Destination-oriented elevators shall provide tactile car identification complying with 703.2 on both jambs of the hoistway immediately below the floor designation....
-
407.2.3.2 Car Designations
Destination-oriented elevators shall provide tactile car identification complying with 703.2 on both jambs of the hoistway immediately below the floor designation....
-
4.1.6(3)(a) Ramps
(a) Ramps: Curb ramps and interior or exterior ramps to be constructed on sites or in existing buildings or facilities where space limitations prohibit the use of a 1:12 slope or less may...
-
M302.1 General
EXCEPTION: Where weight scales contain wheelchair spaces complying with M303 and also provide a seat integral to the equipment, the scales shall not be required to comply with M302....
-
Equipment and furniture.
of temporary or movable structures, such as furniture, equipment, and display racks is not readily achievable to the extent that it results in a significant loss of selling or serving space...
-
M303.3.3 Ramped (Section-by-Section Analysis)
The MDE NPRM proposed that for equipment with a change in level at the entry of a wheelchair space, level changes greater than ½ inch high would be required to be ramped and comply with...
- Sears Brands, LLC Craftsman 10 in. Digital LaserTrac® Level
- Husky 10" Multi-Function Standard Digital Level
- Access Board: Signs
-
406.5 Location
Curb ramps and the flared sides of curb ramps shall be located so that they do not project into vehicular traffic lanes, parking spaces, or parking access aisles....
-
Polling place violations that can be remediated with temporary measures
entrance to the voting area contains a fire extinguisher and two hand sanitizers that protrude more than 4 inches into the route and the bottom of each object is more than 27 inches above the floor...
-
406.5 Location
Curb ramps and the flared sides of curb ramps shall be located so that they do not project into vehicular traffic lanes, parking spaces, or parking access aisles....
-
A4.5.1 General
It is recognized that the coefficient of friction varies considerably due to the presence of contaminants, water, floor finishes, and other factors not under the control of the designer...
-
405.2 Slope
EXCEPTION: In existing sites, buildings, and facilities, ramps shall be permitted to have running slopes steeper than 1:12 complying with Table 405.2 where such slopes are necessary due to space...
-
405.2 Slope
EXCEPTION: In existing sites, buildings, and facilities, ramps shall be permitted to have running slopes steeper than 1:12 complying with Table 405.2 where such slopes are necessary due to space...
-
405.2 Slope
EXCEPTION: In existing sites, buildings, and facilities, ramps shall be permitted to have running slopes steeper than 1:12 complying with Table 405.2 where such slopes are necessary due to space...