Truncated domes in a detectable warning surface shall have a center-to-center spacing of 1.6 inches (41 mm) minimum and 2.4 inches (61 mm) maximum, and a base-to-base spacing of 0.65 inch...
Search Results "Check Writing Surface"
-
705.1.2 Dome Spacing
-
11B-503.3.3 Marking
The area within the borderlines shall be marked with hatched lines a maximum of 36 inches (914 mm) on center in a color contrasting with that of the aisle surface....
-
11B-404.2.9 Door and gate opening force
and the centerline of the second push plate shall be 30 inches (762 mm) minimum and 44 inches (1118 mm) maximum above the floor or ground surface....
- Project LETS (Let's Erase the Stigma)
-
11B-505.10.3 Bottom extension at stairs
Extension shall return to a wall, guard, or the landing surface, or shall be continuous to the handrail of an adjacent stair flight....
-
809.2.2 Turning Space
For example, in kitchens, 804.3.1 requires at least one work surface with clear floor space complying with 306 to be centered beneath....
-
11B-703.7.2.6 Toilet and bathing facilities geometric symbols
Geometric symbols at entrances to toilet and bathing rooms shall be mounted at 58 inches (1473 mm) minimum and 60 inches (1524 mm) maximum above the finish floor or ground surface measured...
-
11B-703.7.2.6 Toilet and bathing facilities geometric symbols
Geometric symbols at entrances to toilet and bathing rooms shall be mounted at 58 inches (1473 mm) minimum and 60 inches (1524 mm) maximum above the finish floor or ground surface measured...
-
4.17.6 GRAB BARS
Grab bars may be mounted with any desired method as long as they have a gripping surface at the locations shown and do not obstruct the required clear floor area....
-
11B-503.3.3 Marking
The area within the borderlines shall be marked with hatched lines a maximum of 36 inches (914 mm) on center in a color contrasting with that of the aisle surface....
-
R409.10.2 Top Extension at Stairways
Extensions shall return to a wall, guard, or the landing surface, or shall be continuous to the handrail of an adjacent stair flight....
-
11B.707.7.1.1 Vertically mounted display screen
or tipped away from the viewer less than 30 degrees, the center line of the display screen and other display devices shall be no more than 52 inches (1321 mm) above the floor or ground surface...
-
11B-1009.2.2 Seat location
The deck surface between the centerline of the seat and the pool edge shall have a slope not steeper than 1:48. FIGURE 11B-1009.2.2 POOL LIFT SEAT LOCATION...
-
Door King Inc. 6400 In-Ground Gate Operators Video
Requires the Registered User plan or above. Login!
-
904.4.2 Forward Approach
A portion of the counter surface that is 30 inches (760 mm) long minimum and 36 inches (915 mm) high maximum shall be provided....
-
11B.707.7.1.3 Horizontally mounted display screen
60 degrees to 90 degrees (horizontal) from vertical, the center line of the display screen and other display devices shall be no more than 34 inches (864 mm) above the floor or ground surface...
-
Bus boarding and alighting areas
Bus boarding and alighting areas must be in compliance with the ADA-ABA Guidelines (Section 810.2), which address surfaces (sturdy), dimensions (96" long x 60" wide); connection to sidewalks...
-
§ 382.57(c)(6)(iv)(B) Tactile symbols
Function key surfaces must have tactile symbols as follows: Enter or Proceed key: raised circle; Clear or Correct key: raised left arrow; Cancel key: raised letter ex; Add Value key: raised...
-
505.10.3 Bottom Extension at Stairs
Extension shall return to a wall, guard, or the landing surface, or shall be continuous to the handrail of an adjacent stair flight....
-
11B-407.4.6.2.1 Size and shape
Buttons shall have square shoulders, be ¾ inch (19.1 mm) minimum in their smallest dimension and be raised 1/8 inch (3.2 mm) plus or minus 1/32 inch (0.8 mm) above the surrounding surface...
-
Fixed tactile maps
Placement on a horizontal or near horizontal surface provides the map reader with a real world orientation....
-
R406.3 Unobstructed Side Reach
approach to an element and the side reach is unobstructed, the high side reach shall be 1220 mm (4.0 ft) maximum and the low side reach shall be 380 mm (1.25 ft) minimum above the finish surface...
-
§ 38.31(c)
doorways, including doorways in which lifts or ramps are installed, shall have outside light(s) which, when the door is open, provide at least 1 foot-candle of illumination on the street surface...
-
4.34.6.6* RANGES AND COOKTOPS
If ovens or cooktops have knee spaces underneath, then they shall be insulated or otherwise protected on the exposed contact surfaces to prevent burns, abrasions, or electrical shock....