In pedestrian circulation paths other than shared use paths, the clear width of curb ramp runs, blended transitions, and turning spaces shall be 1.2 m (4.0 ft) minimum....
Search Results "Clear Pier Space"
Commonly Searched Documents
-
R304.5.1.1 Pedestrian Circulation Paths Other Than Shared Use Paths
-
11B-707.9.2 Point-of-sale devices at check stands and sales or service counters
Where point-of-sale devices are provided at check stands and sales or service counters, they shall comply with Section 11B-707.9.1, and shall also comply with Sections 11B-707.2 _|Clear...
-
5.1.5 Floor Height
Where the floor at the entrance to the camp shelter is elevated above the ground surface, the floor shall be 17 (430 mm) high minimum to 19 inches (485 mm) high maximum measured from the clear...
-
5.1.5 Floor Height
Where the floor at the entrance to the camp shelter is elevated above the ground surface, the floor shall be 17 (430 mm) high minimum to 19 inches (485 mm) high maximum measured from the clear...
-
1130A.1 General
An accessible route shall be provided through all rooms and spaces of the dwelling unit....
-
20. Does topping off a play surface trigger its replacement with an accessible surface?
surface along accessible routes located within the boundary of the play area, including the entry and exit points of the ground level play components required to be accessible, as well as at clear...
-
Kitchens, Kitchenettes, or Wet Bars [9.2.2(7)]
Kitchens, Kitchenettes, or Wet Bars [9.2.2(7)] Clear floor space for either a forward or a side approach is permitted for cabinets, counters, sinks, and appliances....
-
1133A.2, Item 2
A clear floor space at least 30 inches (762 mm) by 48 inches (1219 mm) that allows either a parallel or forward approach shall be provided at the kitchen sink and all other fixtures or appliances...
-
Floor Height [1013.4]
If the tent platform floor is raised above grade, the floor height must be no more than 19 inches when measured from the clear ground space to the tent platform surface....
-
2.9.1 Natural Elements
However, safety regulations or Forest Service construction and maintenance standards may define clear space and limit the allowable extension of natural protruding objects over the ORAR...
-
1013.3 Slope
This section requires the slope of the surface of tent pads, tent platforms, and clear ground spaces to not be steeper than 1:48 in any direction....
-
1133A.2, Item 2
A clear floor space at least 30 inches (762 mm) by 48 inches (1219 mm) that allows either a parallel or forward approach shall be provided at the kitchen sink and all other fixtures or appliances...
- Seton Florida State Fine Signs - $100 Fine F.S. 316.14
-
1134A.5 Bathtubs
Floor space....
-
Applying the Accessibility Standards to the Plan, Installation, and Maintenance of Ground Level Accessible Routes for Playgrounds
Is the surface for the accessible route, clear ground space and turning space compliant with ASTM F1951-99 Standard Specification for Determination of Accessibility of Surface Systems Under...
-
Obstructed High Reach: ADA Standard Section 308.3.2
Section 308.3.2 covers the current ADA Standards for obstructed high side reach.
-
11B-308.3.2 Obstructed high reach
Where a clear floor or ground space allows a parallel approach to an element and the high side reach is over an obstruction, the height of the obstruction shall be 34 inches (864 mm) maximum...
-
309 Operable Parts
Specifications for operable parts address clear floor space, height, and operating characteristics. Operable parts are required to be located with the reach ranges specified in 308....
-
1008.4.4 Entry Points and Seats
Where play components require transfer to entry points or seats, the entry points or seats shall be 11 inches (280 mm) minimum and 24 inches (610 mm) maximum from the clear floor or ground...
-
Question 10
Is the accessible entrance into the building free of obstacles that block the clear wall and floor space needed for opening the door (between 18 and 42 inches on the latch side of the door...
-
1008.4.4 Entry Points and Seats
Where play components require transfer to entry points or seats, the entry points or seats shall be 11 inches (280 mm) minimum and 24 inches (610 mm) maximum from the clear floor or ground...
-
H6