The guidelines specify that LULA elevator cars be at least 42 inches wide and 54 inches deep with a door on the narrow end providing at least 32 inches clear width (408.4.1)....
Search Results "Door Clear Width"
-
LULA Elevator Dimensions
-
Taking Measurements
Using a tape measure to measure the width of a parking space Measuring Door Openings Measuring the clear opening of an accessible door requires special care....
- Corbin Russwin Inc. HPSK Push Pull Paddle Trim
- Sargent LS8600 Low Profile Center and Top Latch Concealed Vertical Rods Exit Device
- Corbin Russwin Inc. ED3000 Series Crossbar Exit Device
- Corbin Russwin Inc. ED8000 Pushpad Exit Device
- Allegion Von Duprin 22 Series Exit Devices
- Yale 1800 Series Flatbar Exit Device
- Allegion Falcon 19 Series Exit Devices
- Allegion Falcon XX Series Cross Bar Exit Devices
- Yale 2100 Series Flatbar Exit Device
- TownSteel MRXL Grade 1 Mortise Lock with Ligature Resistant Rose Trim
- Corbin Russwin Inc. FE6700 Storm Shutter Multi-Point Latching System
- Yale 6000 Series Commercial Exit Devices
- Rockwood Manufacturing Company 596S Hospital Push Pull Latch 2-3/4" Backset
- Rockwood Manufacturing Company 596 Hospital Push Pull Latch 5" Backset
-
Check-Out Aisles and Sales and Service Counters
The requirement that knee and toe space be provided where only clear floor space for a forward approach to a sales and service counter is provided is not a new requirement....
-
DSA Drawing 11B-406-7 Parallel Curb Ramp next to a Curb and Gutter (2016 CBC)
Requires the Premium User plan or above. (Login or upgrade your account!)
-
DSA Drawing 11B-406-10 Parallel Curb Ramp with No Gutter (2016 CBC)
Requires the Premium User plan or above. (Login or upgrade your account!)
-
DSA Drawing 11B-406-9 Parallel Curb Ramp next to a Curb and Gutter (2016 CBC)
Requires the Premium User plan or above. (Login or upgrade your account!)
-
711.4.6 Floor fire doors
Floor fire doors used to protect openings in fire-resistance-rated floors shall be tested in the horizontal position in accordance with ASTM E 119, and shall achieve a fire-resistance rating...
-
16. Opening Building Doors
For paratransit services, a passenger's request for the driver to open an exterior entry door to a building to provide boarding and/or alighting assistance to a passenger with a disability...
-
11B-233.3.1.2.6 Public housing facility site impracticality
ETA Editor's Note This section of the 2019 California Building Code was amended by the Division of the State Architect. The requirements in this section were previously found in...