technology Available with electric tankless water heaters New streamlined contemporary design ADA, ANSI, UFAS and TAS compliant Serves 1 - 2 users at a time Standard lavatory spacing...
Search Results "Circulation Space"
- Bradley 2-Station Express Lavatory System SS-2N
- Bradley 3-Station Express Lavatory System SS-3N
- Whitehall Mfg. 3374-WSF Hot & Cold Hemispherical Widespread Pushbuttons Pneumatic Valve Conical Faucet
- Meridian Presenza Family Kiosk
- Bradley 3-Station Express Lavatory System MG-3
-
1009.6.1 Travel distance
The maximum travel distance from any accessible space to an area of refuge shall not exceed the exit access travel distance permitted for the occupancy in accordance with Section 1017.1....
-
11B-810.1.2 Baggage systems
Baggage check-in and retrieval systems shall be on an accessible route complying with Section 11B-402 and shall have space immediately adjacent complying with Section 11B-302....
-
11B-810.1.2 Baggage systems
Baggage check-in and retrieval systems shall be on an accessible route complying with Section 11B-402 and shall have space immediately adjacent complying with Section 11B-302....
-
Toilet Compartments: ADA Standard Section 213.3.1
Section 213.3.1 covers scoping requirements in the current ADA Standards for toilet compartments.
-
11B-604.8.1.2 Doors
Doors shall not swing into the clear floor space or clearance required for any fixture....
-
11B-604.8.1.2 Doors
Doors shall not swing into the clear floor space or clearance required for any fixture....
-
Surface and Slope [1012.4 and 1012.5]
The surface of parking spaces and pull-up spaces for RVs must be firm and stable....
- Rebuilding Together Alexandria - Alexandria, VA
-
Doors in Series and Gates in Series: ADA Standard Section 404.2.6
Section 404.2.6 covers the current ADA Standards for doors in series and gates in series.
-
11B-404.2.6 Doors in series and gates in series
The distance between two hinged or pivoted doors in series and gates in series shall be 48 inches (1219 mm) minimum plus the width of doors or gates swinging into the space....
-
SELF-SERVICE STORAGE
[DSA-AC] Building or facility designed and used for the purpose of renting or leasing individual storage spaces to customers for the purpose of storing and removing personal property on...
-
11B-404.2.6 Doors in series and gates in series
The distance between two hinged or pivoted doors in series and gates in series shall be 48 inches (1219 mm) minimum plus the width of doors or gates swinging into the space....
-
SELF-SERVICE STORAGE
[DSA-AC] Building or facility designed and used for the purpose of renting or leasing individual storage spaces to customers for the purpose of storing and removing personal property on...
-
11B-502.6.3 Location
A parking space identification sign shall be visible from each parking space....
-
11B-502.6.3 Location
A parking space identification sign shall be visible from each parking space....
-
11B-502.6.3 Location
A parking space identification sign shall be visible from each parking space....
- Mayer-Rothschild Foundation: Determination of Grab Bar Specifications for Independent and Assisted Transfers in Residential Care Settings
-
General: ADA Standard Section 306.2.1
Section 306.2.1 of the ADA Standards covers information in the current ADA Standards for toe clearance.
-
11B-802.5 Semi-ambulant seats
Semi-ambulant seats shall provide at least 24 inches (610 mm) clear leg space between the front of the seat to the nearest obstruction or to the back of the seat immediately in front....