If the entry has a vestibule, is there a 30-inch by 48-inch clear floor space inside the vestibule where a wheelchair or scooter user can be outside the door swing?...
Search Results "Wheelchair Passing Space"
Commonly Searched Documents
-
H6
-
3. Lavatory knee clearance
Lavatory knee clearance: To allow persons who use wheelchairs to pull under the lavatory and to use the faucet hardware, the following features need to be provided -- a 29-inch-high clearance...
-
Accessible Classroom - Chevron Style
This style of classroom set-up affords the greatest flexibility and space for access....
-
Play Tables
Where play tables are located on an accessible route, the wheelchair knee clearance minimums are: 24 inches (610 mm) high minimum 30 inches (760 mm) wide minimum...
-
Identification of available accessible seating. (Section-by-Section Analysis)
The proposed rule specifically prohibits the practice of "steering" individuals with disabilities to certain wheelchair spaces so that the facility can maximize potential ticket sales for...
-
Common Errors in ADA Design
We are pleased to pass along the following Common Errors in ADA Design to you....
-
Accessible Route
The proposed rule contained a requirement that where elevators or wheelchair lifts are provided on an accessible route to wheelchair spaces or designated aisle seats, they shall be provided...
-
D6
If an entry has a vestibule, is there a 30-inch by 48-inch clear floor space inside the vestibule where a wheelchair or scooter user can be outside the swing of a hinged door?...
-
J6
Is the bottom of the apron of the fountain 27 inches above the floor so that it provides the space needed for a person who uses a wheelchair to pull up under it but is not a hazard to people...
-
§ 35.138(d)(3) Sales limited to less than four tickets
limits sales of tickets to fewer than four seats per patron, then the public entity is only obligated to offer as many seats to patrons with disabilities, including the ticket for the wheelchair...
-
407.4.8.1.3 Floor Arrival
As the car passes a floor and when a car stops at a floor served by the elevator, the corresponding character shall illuminate....
-
Lifts and Elevators
The door into the elevator or lift and the space within must be wide enough to accommodate wheelchairs and other mobility devices....
-
9.5 LOCKER ROOMS
When double-tier lockers are used, only the bottom row of lockers may be assigned for use by wheelchair users....
-
Interacting with People with Physical Disabilities
The chair is part of the personal body space of the person who uses it. Stand next to the person’s wheelchair, rather than leaning or holding onto it....
-
Medical Device Manufacturers
accessible features in some of their products such as patient support surfaces that are height adjustable, transfer and positioning supports, and scales designed for use by patients seated in a wheelchair...
-
Team and Player Seating
This provision, which derives from the Board’s guidelines for recreation facilities, requires at least one wheelchair space in team or player seating areas serving areas of sports activity...
-
Access to Approach, Enter, and Exit Work Areas
Access for “approach, entry, and exit” requires a connecting accessible route to the work area and a compliant entrance, including entry doors or gates, plus wheelchair space in the work...
-
Platform Size and Surface
Platform Size and Surface To be part of an accessible route, lift platforms must provide the amount of clear space required for wheelchairs in ADAAG 4.2.4....
-
Storage [9.2.2(4)]
Clear floor space for either a forward or side approach is allowed....
-
Single-User Toilet Rooms: Split Plumbing
While the knee and toe clearance required at lavatories may allow a forward approach to door hardware, if placed in the maneuvering space, lavatories interfere with wheelchair maneuvering...
-
Viewing Areas
The clear ground space and turning space may overlap. The turning space requirement is the same as ABAAS section 304.3....
-
11B-407.4.8.1.3 Floor arrival
As the car passes a floor and when a car stops at a floor served by the elevator, the corresponding character shall illuminate. Exception: Reserved....
-
212 and 606 Kitchens, Kitchenettes, Lavatories, and Sinks
The 2010 Standards include an exception that permits the clear floor space to be positioned for a parallel approach at kitchen sinks in any space where a cook top or conventional range is...
-
7b.
[ADA Stds 4.13.9] Yes _____ No _____ A clear floor space on the latch side of the door (pull side) allows a person using a wheelchair or scooter to pull the door open and then...