The Guidelines adequately address the accessible route into and through the dwelling unit by the minimum corridor width and door width specifications, given typical apartment layouts....
Search Results "Shower Door"
Commonly Searched Documents
-
T-turn Maneuvering Space
-
11B-604.3.1 Size
ETA Editor's Note The 2013 CBC 11B-604.3 requirement for clearance in front of accessible water closets exceeds the 2010 ADAS requirement, but a door may swing into the added clearance...
-
Kitchen Counters, Walls, and Floors
Sweeps on kitchen doors to eliminate the thresholds with are tripping hazards....
-
§ 38.77(b)
Without restricting the vestibule space, the assist shall provide support for a boarding passenger from the door through the boarding procedure....
-
11B-604.3.1 Size
ETA Editor's Note The CBC 11B-604.3 requirement for clearance in front of accessible water closets exceeds the 2010 ADAS requirement, but a door may swing into the added clearance....
-
11B-405.8 Handrails
At door landings, handrails are not required on ramp runs less than 6 inches (152 mm) in rise or 72 inches (1829 mm) in length....
-
11B-206.4 Entrances
Entrance doors, doorways, and gates shall comply with Section 11B-404 and shall be on an accessible route complying with Section 11B-402. Exceptions: 1. Reserved....
-
§ 38.155(a)
Without restricting the vestibule space, the assist shall provide support for a boarding passenger from the door through the boarding procedure....
-
11B-405.8 Handrails
At door landings, handrails are not required on ramp runs less than 6 inches (152 mm) in rise or 72 inches (1829 mm) in length....
-
11B-604.3.1 Size
Note The CBC 11B-604.3.1 requirement for maneuvering space in front of accessible water closets exceeds the 2010 ADA Standards requirement for water closet clear floor space, but a door...
-
11B-206.4 Entrances
Entrance doors, doorways, and gates shall comply with Section 11B-404 and shall be on an accessible route complying with Section 11B-402. Exceptions: 1. Reserved....
- Savaria ORION Limited Use/Limited Application Elevator Video
- Hadrian Inc. Gladiator Athletic Lockers
- Gamco Recessed Coverall Combination Towel Dispenser and Waste Receptacle - TW-9
-
5.4.4 Transfer Support Distance from Transfer Surface Recommendations for M301 and M302
surface that is opposite the transfer side (see M301.2.3 and M302.2.3) similar to the provisions in the 2004 ADA and ABA Accessibility Guidelines for grab bars provided at bathtubs and shower...
-
Do facilities in remote locations have to be accessible?
The Forest Service Outdoor Recreation Accessibility Guidelines (FSORAG) provide guidance for campsites, tent pads and platforms, viewing overlooks, outdoor showers, picnic tables, fire rings...
-
III-4.4400 Continuing obligation
If the hotel were newly constructed, it would be required to provide five fully accessible rooms (including one with a roll-in shower) and four rooms that are equipped with visual alarms...
-
Transfer Surface Height (M301.2.1 and M302.2.1)
., toilet seats, shower seats, dressing benches)....
- EZCurb Ramp - Vertical Barrier Removal Instructional Video
-
11B-201.1 Scope, 11B-201.2 Application based on building or facility use, 11B-202.2 Additions, 11B-202.3 Alterations
Example: A facility proposes to replace several of the windows and doors in a hospital. This type of replacement project affects a small portion of many rooms within a building....
- American Specialties Recessed Paper Towel Dispenser and Removable Waste Receptacle 204623
-
This is a great unit but it's not "recessed", it's semi-recessed.
you place this unit next to the accessible lavatory or other required clear space and don't allow room for the projection, it may interfere with the minimum required clear floor space, door...
- Rebuilding Together Lincoln County - Boothbay Harbor, ME
- Long Island Center for Independent Living, Inc. (LICIL) - Levittown, NY