For instance, combining visual and audible alerts will reach a greater audience than either method would by itself....
Search Results "Maximum Reach Depth"
-
NOTIFICATION
-
What Does Your Event Need? Creating a Needs Assessment
Before reaching out to facilities to find the best choice for your event, you need to identify the needs of your audience....
-
What Do I Do If I Think That I'm Being Discriminated Against?
For information and instructions on reaching your local office, call: (800) 669-4000 (Voice) (800) 669-6820 (TDD) (In the Washington, D.C. 202 Area Code, call 202...
-
CONCLUSION
The raised porches also do not comply with the 2010 Standards because the revised public entrance provisions must be read as reaching the same outcome as the 1991 public entrance provisions...
-
Regulatory Impact Analysis.
requirements for each of the following eight existing elements will exceed monetized benefits by more than $100 million when using the 1991 Standards as the comparative baseline: side reach...
- Fulton County, GA Self Evaluation Report
-
Expert Report of Douglas J. Anderson, RAS, CASP, LCM Architects (August 8, 2018)
Sidewalks & Walkways: The cross slope in the designated accessible route exceeds the maximum slope allowed of 1:48 (1991 ADA Stds 4.3.7; 2010 ADA Stds 403.3)....
- MD Support: The Eyes of the Macular Degeneration Community
-
11B-606.2 Clear floor space
minimum above the finish floor or ground shall be permitted at lavatories and sinks used primarily by children 6 through 12 years where the rim or counter surface is 31 inches (787 mm) maximum...
-
11B-606.2 Clear floor space
minimum above the finish floor or ground shall be permitted at lavatories and sinks used primarily by children 6 through 12 years where the rim or counter surface is 31 inches (787 mm) maximum...
-
11B-704.2.1.2 Forward approach
Where a forward approach is provided, the distance from the front edge of a counter within the telephone enclosure to the face of the telephone unit shall be 20 inches (510 mm) maximum....
-
Section 35.151(b)(3) Alterations to historic facilities
Currently, the regulation provides that alterations to historic facilities shall comply to the maximum extent feasible with section 4.1.7 of UFAS or section 4.1.7 of the 1991 Standards....
-
Detectable Warnings
The proposed rule, consistent with the original ADAAG, provided specifications for the coordination of vehicles and platforms, including maximum changes in level (plus or minus e inch) and...
-
Revolving Doors or Turnstiles
While automated revolving doors, if large enough, may be usable by people with disabilities, certain questions remain about the appropriate maximum speed, minimum diameter, compartment size...
-
Fixed Shower Head Height
The original ADAAG allowed fixed shower heads 48 inches high maximum to be used instead of the required hand-held unit in "unmonitored facilities where vandalism is a consideration."...
-
703.3.1 Dimensions and Capitalization
Table 703.3.1 Braille Dimensions Measurement Range Minimum in Inches Maximum in Inches Dot base diameter 0.059 (1.5 mm) to 0.063 (1.6 mm)...
-
610.3 Shower Compartment Seats
The top of the seat shall be 17 inches (430 mm) minimum and 19 inches (485 mm) maximum above the bathroom finish floor. Seats shall comply with 610.3.1 or 610.3.2....
-
R302.5 Grade
Where pedestrian access routes are not contained within a street or highway right-of-way, the grade of pedestrian access routes shall be 5 percent maximum. Advisory R302.5 Grade....
-
R302.7.2 Vertical Surface Discontinuities
Vertical surface discontinuities shall be 13 mm (0.5 in) maximum....
-
Ramp
The minimum length was 8 inches and the maximum length was 11 inches....
-
4.4.1* GENERAL
Free-standing objects mounted on posts or pylons may overhang 12 in (305 mm) maximum from 27 in to 80 in (685 mm to 2030 mm) above the ground or finished floor (see Fig. 8(c) and (d))....
-
Obstructions [4.7.8]
Where space at the top is less than 48 inches, side flares must have a maximum slope of 1:12 instead of 1:10 at the curb face....
-
COMPARISON OF OBJECTIVE MEASURES AND ENERGY COSTS
All correlations were strong (>0.85; maximum 1.0 for a perfect correlation), except for the medium correlation between penetrometer firmness and velocity (r = −0.6)....
-
1014.2.1 Transfer Access
The camp shelter floor at the entrance is required to be 19 inches high maximum measured from the clear ground space....