EXCEPTION: In existing elevators, where a new car operating panel complying with 407.4.6 is provided, existing car operating panels shall not be required to comply with 407.4.6....
Search Results "General Exception"
Commonly Searched Documents
-
407.4.6 Elevator Car Controls
-
1009.6.1 Pool Stairs
EXCEPTION: Pool step riser heights shall not be required to be 4 inches (100 mm) high minimum and 7 inches (180 mm) high maximum provided that riser heights are uniform....
-
505.2 Where Required
EXCEPTION: In assembly areas, handrails shall not be required on both sides of aisle ramps where a handrail is provided at either side or within the aisle width....
-
§100.148 Effective date.
[62 FR 66433, Dec. 18, 1997] The privilege under this subpart applies to self-tests conducted both before and after January 30, 1998, except that a self-test conducted before January...
-
4.1.3(16)(b)
EXCEPTION: Building directories, menus, and all other signs which are temporary are not required to comply....
-
3.1.3.1 Slope of Vehicle Parking Areas
Exception. When the surface is not paved, slopes not steeper than 1:33 (3 percent) shall be permitted where necessary for drainage. ...
-
6.6 Clear Width
Exception: At dune crossings, the clear width of beach access routes that are not removable shall be permitted to be reduced to 48 inches (1220 mm) minimum....
-
502.4 Floor or Ground Surfaces
EXCEPTION: Slopes not steeper than 1:48 shall be permitted. ...
-
1018.4 Clear Width
EXCEPTION: At dune crossings, the clear width of beach access routes that are not removable shall be permitted to be reduced to 48 inches (1220 mm) minimum....
-
Car Controls [§407.4.6 and §407.4.7]
Car Controls [§407.4.6 and §407.4.7] If more than one car control panel is provided in a car, both must comply (except in existing cars where only 1 panel must comply)....
-
11B-306.2.2 Maximum depth
Exception: Toe clearance shall extend 19 inches (483 mm) maximum under lavatories required to be accessible by Section 11B-213.3.4. ...
-
§ 37.135(b) Initial submission
Except as provided in §37.141 of this part, each entity shall submit its initial plan for compliance with the complementary paratransit service provision by January 26, 1992, to the appropriate...
-
§ 37.203(c)
(c) Except as provided in paragraph (d) of this section, when a lift is discovered to be inoperative, the entity shall take the vehicle out of service before the beginning of the vehicle's...
-
11B-407.2.2.4 Differentiation
ETA Editor's Note Lacking certain Exceptions allowed by 2010 ADAS, and imposing additional requirements regarding visible signals, the preceding CBC requirements pertaining to elevator...
-
11B-705.1.1.4 Resiliency
Exception: Detectable warning surfaces at curb ramps, islands or cut-through medians shall not be required to comply with Section 11B-705.1.1.4....
-
11B-306.2.2 Maximum depth
Exception: Toe clearance shall extend 19 inches (483 mm) maximum under lavatories required to be accessible by Section 11B-213.3.4. ...
-
Section 36.102 Application (Preamble, Section-by-Section Analysis)
Except as provided in § 36.206, ‘‘Retaliation or coercion,’’ this part does not apply to individuals other than public accommodations or to public entities....
-
Historic Preservation
determines that compliance with the requirements for accessible routes, entrances, or toilet facilities would threaten or destroy the historic significance of the building or facility, the exceptions...
-
11B-228.3.2.1 Public use or common use EVCS
Exception: All drive-up EVCS shall comply with Section 11B-812....
-
Doors: ADA Standard Section 604.8.1.2
Section 604.8.1.2 covers the current ADA Standards for wheelchair accessible compartment doors.
-
Designations: ADA Standard Section 216.2
Section 216.2 covers scoping requirements in the current ADA Standards for sign designations.
-
Protrusion Limits: ADA Standard Section 307.2
Section 307.2 covers the current ADA Standards for protrusion limits.
-
Car Dimensions and Doors: ADA Standard Section 408.4.1
Section 408.4.1 covers the current ADA Standards for the car dimensions and doors of limited-use/limited-application elevators.
-
Within a Site: ADA Standard Section 206.2.2
Section 206.2.2 covers the scoping requirements for accessible routes within a site in the most current ADA Standards.