The height of the transfer platform shall comply with 1009.4.2....
Search Results "Transfer Wall"
Commonly Searched Documents
-
1009.5.3 Height
-
1009.5.3 Height
The height of the transfer platform shall comply with 1009.4.2....
-
11B-1009.5.3 Height
The height of the transfer platform shall comply with Section 11B-1009.4.2....
-
11B-1009.5.3 Height
The height of the transfer platform shall comply with Section 11B-1009.4.2....
-
11B-1009.5.3 Height
The height of the transfer platform shall comply with Section 11B-1009.4.2....
-
11B-1009.5.5 Surface
The surface of the transfer system shall not be sharp and shall have rounded edges....
-
1009.5.5 Surface
The surface of the transfer system shall not be sharp and shall have rounded edges....
-
1009.5.5 Surface
The surface of the transfer system shall not be sharp and shall have rounded edges....
-
11B-1009.5.5 Surface
The surface of the transfer system shall not be sharp and shall have rounded edges....
-
11B-1009.5.5 Surface
The surface of the transfer system shall not be sharp and shall have rounded edges....
-
1009.5.5 Surface
The surface of the transfer system shall not be sharp and shall have rounded edges....
-
4.1.2 Surface Design of Examination Tables and Chairs
Thus, contouring must be addressed in considering minimum height standards for accessibility of transfer surfaces (Section 5.1.4)....
-
Surface
Surface The surface of the transfer platform and steps must not be sharp and must have rounded edges to prevent injuries....
-
Platform Height
Platform Height Transfer platforms must be between 16 and 19 inches high, measured from the deck....
-
5.4.4.1 Transfer Support Distance from Transfer Surface Recommendation for Stretchers
5.4.4.1 Transfer Support Distance from Transfer Surface Recommendation for Stretchers The Committee recommends locating the transfer support along the long side of the of the transfer...
-
11B-608.2.1 Reserved
ETA Editor's Note The transfer type shower compartments prescribed by 2010 ADAS 608.2.1 are not recognized as an accessible shower in California....
-
Transfer Surface Size: Equipment Used by Patients in a Seated Position (M302.2.2)
On diagnostic equipment used by patients in a seated position, M302.2.2 would require the size of the transfer surface to be 21 inches wide minimum and 15 inches deep minimum....
-
1009.5.6 Size
Each transfer step shall have a tread clear depth of 14 inches (355 mm) minimum and 17 inches (430 mm) maximum and shall have a tread clear width of 24 inches (610 mm) minimum. ...
-
11B-1009.5.6 Size
Each transfer step shall have a tread clear depth of 14 inches (356 mm) minimum and 17 inches (432 mm) maximum and shall have a tread clear width of 24 inches (610 mm) minimum....
-
11B-1009.5.6 Size
Each transfer step shall have a tread clear depth of 14 inches (356 mm) minimum and 17 inches (432 mm) maximum and shall have a tread clear width of 24 inches (610 mm) minimum....
-
11B-1002.6 Transfer devices for use with amusement rides
When using a transfer device to access an amusement ride, the least number of transfers and the shortest distance is most usable....
-
11B-1002.6 Transfer devices for use with amusement rides
When using a transfer device to access an amusement ride, the least number of transfers and the shortest distance is most usable....
-
11B-1002.6 Transfer devices for use with amusement rides
Transfer devices for use with amusement rides should permit individuals to make independent transfers to and from their wheelchairs or mobility devices....
-
5.3.2.1 Transfer Sides for Stretchers
5.3.2.1 Transfer Sides for Stretchers. The transfer surface shall be located to provide the ability to transfer from a mobility device onto both long sides of the surface....