4 [§ 4.7.2] The gutter is the part of the street that borders the curb. To measure the gutter slope, place the level in the same position as the arrow in the illustration, with...
Search Results "Ticket Counter"
Commonly Searched Documents
-
4 [§ 4.7.2]
-
1133A.4 Countertops
1133A.4 Countertops. Kitchen countertops shall comply with this section and shall be provided with the following:
-
Transition to Street [§406.2]
Transition to Street [§406.2]
-
1133A.4 Countertops
Kitchen countertops shall comply with this section and shall be provided with the following:
-
1133A.4 Countertops
Kitchen countertops shall comply with this section and shall be provided with the following: A minimum linear length of 30 inches (762 mm) of countertop shall be provided for...
-
Slope [4.7.2]
Severe counter slopes can do the same thing and cause footrests to scrape....
-
F231.4.2 Partitions
Where solid partitions or security glazing separate visitors from detainees, at least one of each type of cubicle or counter partition shall comply with 904.6....
-
231.4.2 Partitions
Where solid partitions or security glazing separate visitors from detainees at least one of each type of cubicle or counter partition shall comply with 904.6....
-
§27.71(k)(5)(i)(D)
(D) Where receipts, tickets, or other outputs are provided as a result of a transaction, speech output must include all information necessary to complete or verify the transaction, except...
-
§ 27.71(k)(5)(i)(D)
(D) Where receipts, tickets, or other outputs are provided as a result of a transaction, speech output must include all information necessary to complete or verify the transaction, except...
-
231.4.2 Partitions
Where solid partitions or security glazing separate visitors from detainees, at least one of each type of cubicle or counter partition shall comply with 904.6....
-
11B-231.4.2 Partitions
Where solid partitions or security glazing separate visitors from detainees at least one of each type of cubicle or counter partition shall comply with Section 11B-904.6....
-
11B-231.4.2 Partitions
Where solid partitions or security glazing separate visitors from detainees at least one of each type of cubicle or counter partition shall comply with Section 11B-904.6....
-
11B-231.4.2 Partitions
Where solid partitions or security glazing separate visitors from detainees at least one of each type of cubicle or counter partition shall comply with Section 11B-904.6....
-
Height: ADA Standard Section 902.3
The tops of dining surfaces and work surfaces shall be 28 inches (710 mm) minimum and 34 inches (865 mm) maximum above the finish floor or ground.
-
11B-902.3 Height
The tops of dining surfaces and work surfaces shall be 28 inches (711 mm) minimum and 34 inches (864 mm) maximum above the finish floor or ground.
-
231.4 Visiting Areas
231.4 Visiting Areas. Visiting areas shall comply with 231.4.
-
F231.4 Visiting Areas
Visiting areas shall comply with F231.4.
-
11B-231.4 Visiting areas
Visiting areas shall comply with 11B-231.4.
-
231.4 Visiting Areas
Visiting areas shall comply with 231.4.
-
1133A.4.1 Exceptions
Exceptions: Stone, cultured stone and tiled countertops may be used without meeting the repositioning requirements. Two 15-inch (381 mm) wide minimum breadboards may...
-
1133A.4, Item 1
1. A minimum linear length of 30 inches (762 mm) of countertop shall be provided for the kitchen sink installation.
-
7.3(3)
(3) Signage identifying accessible check-out aisles shall comply with 4.30.7 and shall be mounted above the check-out aisle in the same location where the check-out number or type of...
-
4.7.2 Slope
Slopes of curb ramps shall comply with 4.8.2. The slope shall be measured as shown in Fig. 11. Transitions from ramps to walks, gutters, or streets shall be flush and free of abrupt...