1013.3 Height. Required guards shall not be less than 42 inches (1067 mm) high, measured vertically as follows: 1. From the adjacent walking surfaces; 2. On stairs,...
Search Results "Means of Egress Signage"
-
1013.3 Height
-
1009.2, Item 10
10. Exterior areas for assisted rescue complying with Section 1009.7 serving exits at the level of exit discharge.
-
1015.3 Height
Required guards shall not be less than 42 inches (1067 mm) high, measured vertically as follows: From the adjacent walking surfaces. On stairways and stepped aisles,...
-
1011.5.2 Riser height and tread depth
... Exceptions: 4. See California Fire Code Chapter 11 and California Existing Building Code for the replacement of existing stairways. [DSA-AC] For applications listed in...
-
1018.5 Aisles in other than assembly spaces and Groups B and M
In other than rooms or spaces used for assembly purposes and Group B and M occupancies, the minimum clear aisle capacity shall be determined by Section 1005.1 for the occupant load...
-
1018.3 Aisles in Groups B and M
1018.3 Aisles in Groups B and M. In Group B and M occupancies, the minimum clear aisle width shall be determined by Section 1005.1 for the occupant load served, but shall not be less...
-
1009.8.1 System requirements
Two-way communication systems shall provide communication between each required location and a central control point location approved by the fire department. Where the central...
-
1009.8.1 System requirements
Two-way communication systems shall provide communication between each required location and the fire command center or a central control point location and a central control point...
-
1018.3 Aisles in Groups B and M
In Group B and M occupancies, the minimum clear aisle width shall be determined by Section 1005.1 for the occupant load served, but shall be not less than that required for corridors...
-
1018.5 Aisles in other than assembly spaces and Groups B and M
In other than rooms or spaces used for assembly purposes and Group B and M occupancies, the minimum clear aisle capacity shall be determined by Section 1005.1 for the occupant load...
-
1015.3 Height
Required guards shall not be less than 42 inches (1067 mm) high, measured vertically as follows: From the adjacent walking surfaces. On stairways and stepped aisles, from the...
-
1011.5.2 Riser height and tread depth
... Exceptions: 4. See California Fire Code Chapter 11 and California Existing Building Code for the replacement of existing stairways. [DSA-AC] For applications listed in...
-
1010.1.8 Door arrangement
Space between two doors in a series shall be 48 inches (1219 mm) minimum plus the width of a door swinging into the space. Doors in a series shall swing either in the same direction...
- Yale 1500 Series Traditional Exit Devices
- Trimco LDH100 Series Lockdown Hardware
- Stanley QRM 100 Series Grade 1 Extra Heavy Duty Exit Devices
- DORMA 8000 Series Exit Device
- Yale 1800 Series Flatbar Exit Device
- Sargent 8800 Rim Exit Device
- SDC S6000 Spectra Exit Devices
- Allegion Falcon 19 Series Exit Devices
- Allegion Falcon XX Series Cross Bar Exit Devices
- Sargent AD8400 & NB-AD8400 Narrow Stile Concealed Vertical Rod Exit Device
- TownSteel ED1100F Grade 1 Fire Rim Device