EXCEPTION: Doors shall not be required to comply with the maneuvering clearance requirements in 404.2.4.1 for approaches to the push side of swinging doors....
Search Results "Maneuvering Space"
-
409.3 Elevator Doors
-
409.3 Elevator Doors
EXCEPTION: Doors shall not be required to comply with the maneuvering clearance requirements in 404.2.4.1 for approaches to the push side of swinging doors....
-
409.3 Elevator Doors
EXCEPTION: Doors shall not be required to comply with the maneuvering clearance requirements in 404.2.4.1 for approaches to the push side of swinging doors....
-
11B-603.2.3 Door swing
Doors shall not swing into the clear floor space or clearance required for any fixture....
-
11B-603.2.3 Door swing
Doors shall not swing into the clear floor space or clearance required for any fixture....
-
11B-409.3 Elevator doors
Exception: Doors shall not be required to comply with the maneuvering clearance requirements in Section 11B-404.2.4.1 for approaches to the push side of swinging doors....
-
11B-409.3 Elevator doors
Exception: Doors shall not be required to comply with the maneuvering clearance requirements in Section 11B-404.2.4.1 for approaches to the push side of swinging doors....
-
11B-409.3 Elevator doors
Exception: Doors shall not be required to comply with the maneuvering clearance requirements in Section 11B-404.2.4.1 for approaches to the push side of swinging doors....
-
11B-809.10.8.2 Floor space
A floor space 30 inches (762 mm) minimum by 48 inches (1219 mm) minimum shall be provided centered on the lavatory....
-
11B-809.10.8.2 Floor space
A floor space 30 inches (762 mm) minimum by 48 inches (1219 mm) minimum shall be provided centered on the lavatory....
-
11B-305.6 Approach
One full unobstructed side of the clear floor or ground space shall adjoin an accessible route or adjoin another clear floor or ground space....
-
11B-305.6 Approach
One full unobstructed side of the clear floor or ground space shall adjoin an accessible route or adjoin another clear floor or ground space....
-
Character Spacing: ADA Standard Section 703.2.7
Character spacing shall be measured between the two closest points of adjacent raised characters within a message, excluding word spaces....
- Access Board: Toilet Rooms
-
11B-1004.1 Clear floor space
Clear floor or ground spaces required at exercise machines and equipment shall be permitted to overlap. Advisory 11B-1004.1 Clear floor space....
-
11B-1004.1 Clear floor space
Clear floor or ground spaces required at exercise machines and equipment shall be permitted to overlap. Advisory 11B-1004.1 Clear floor space....
-
304 Turning Space
Objects that provide sufficient knee and toe clearance can overlap a limited portion of the turning space. Comment....
-
3.4.4 Clear Ground Space and Turning Space
Each viewing area that is required to be accessible by section 3.4.1 shall have a clear ground or floor space 36 inches (915 mm) minimum by 48 inches (1220 mm) minimum positioned for either...
-
Limited Access Spaces (§203.4)
Limited Access Spaces (§203.4) Spaces accessed only by ladders, catwalks, crawl spaces, or very narrow passageways Examples: lighting/ equipment catwalks at stages and performing...
-
R203 Machinery Spaces
R203 Machinery Spaces. Vaults, tunnels, and other spaces used by service personnel only for maintenance, repair, or monitoring are not required to comply with this document....
-
4.13.4 Double-Leaf Doorways
If doorways have two independently operated door leaves, then at least one leaf shall meet the specifications in 4.13.5 and 4.13.6. That leaf shall be an active leaf.
-
4.13.4 DOUBLE-LEAF DOORWAYS
If doorways have two independently operated door leaves, then at least one leaf shall meet the specifications in 4.13.5 and 4.13.6. That leaf shall be an active leaf.
-
309.2 Clear Floor Space
309.2 Clear Floor Space. A clear floor or ground space complying with 305 shall be provided....
-
Door Swing: ADA Standard Section 304.4
Section 304.4 covers the current ADA Standards for doors swinging into turning spaces.