Search Results "Level Landing"
Commonly Searched Documents
-
Thresholds at Doorways [4.13.8]
-
11B-404.2.4.4 Floor or ground surface
Changes in level, slopes exceeding 1:48, and detectable warnings shall not be permitted. Exceptions: Reserved....
-
4.28.2* Audible Alarms
If provided, audible emergency alarms shall produce a sound that exceeds the prevailing equivalent sound level in the room or space by at least 15 dbA or exceeds any maximum sound level...
-
4.28.2* AUDIBLE ALARMS
If provided, audible emergency alarms shall produce a sound that exceeds the prevailing equivalent sound level in the room or space by at least 15 decibels or exceeds any maximum sound level...
-
1015.2 Where required
Guards shall be located along open-sided walking surfaces, including mezzanines, equipment platforms, aisles, stairs, ramps and landings that are located more than 30 inches (762 mm) measured...
-
Ground Level: ADA Standard Section 1008.2.4.1
At ground level, the clear width of accessible routes shall be 60 inches (1525 mm) minimum. EXCEPTIONS: 1....
-
1013.2 Where required
Guards shall be located along open-sided walking surfaces, including mezzanines, equipment platforms, stairs, ramps and landings that are located more than 30 inches (762 mm) measured vertically...
-
1015.2 Where required
Guards shall be located along open-sided walking surfaces, including mezzanines, equipment platforms, aisles, stairs, ramps and landings that are located more than 30 inches (762 mm) measured...
-
E1-2. Accessible Route
Is the accessible route free of steps and abrupt level changes over 1/2 inch (level changes between 1/4 inch and 1/2 inch should be beveled)?...
-
E1-b
Is the accessible route free of steps and abrupt level changes over 1/2 inch? Yes No Note: level changes between 1/4 inch and 1/2 inch should be beveled)....
-
11B-407.2.1.5 Signals
Call buttons shall have visible signals that will activate when each call is registered and will extinguish when each call is answered. Call buttons shall be internally illuminated...
-
4.10.4(3)
(3) Signals shall be visible from the vicinity of the hall call button (see Fig. 20). In-car lanterns located in cars, visible from the vicinity of hall call buttons, and conforming...
-
4.10.3 Hall Call Buttons
Call buttons in elevator lobbies and halls shall be centered at 42 in (1065 mm) above the floor. Such call buttons shall have visual signals to indicate when each call is registered...
-
4.10.3 HALL CALL BUTTONS
Call buttons in elevator lobbies and halls shall be centered at 42 in (1065 mm) above the floor. Such call buttons shall have visual signals to indicate when each call is registered...
-
11B-407.2.1.5 Signals
Call buttons shall have visible signals that will activate when each call is registered and will extinguish when each call is answered. Call buttons shall be internally illuminated...
-
11B-407.2.1.5 Signals
Call buttons shall have visible signals that will activate when each call is registered and will extinguish when each call is answered. Call buttons shall be internally illuminated...
-
Play Components: ADA Standard Section 1008.4
Ground level play components on accessible routes and elevated play components connected by ramps shall comply with 1008.4....
-
11B-1008.4 Play components
Ground level play components on accessible routes and elevated play components connected by ramps shall comply with Section 11B-1008.4....
-
f-ii
Is the change in level from the floor to the lift surface ramped or beveled? [ADA Standards §§ 4.11.2, 4.5.2] Yes No...
-
405.4 Floor or Ground Surfaces
Changes in level other than the running slope and cross slope are not permitted on ramp runs....
-
405.4 Floor or Ground Surfaces
Changes in level other than the running slope and cross slope are not permitted on ramp runs....
-
1007.8 Two-way communication
A two-way communication system shall be provided at the elevator landing on each accessible floor that is one or more stories above or below the story of exit discharge complying with Sections...
-
21.1 Q. Is a dwelling unit that has a split entry foyer...required to be accessible if it is a ground floor unit in a covered multifamily dwelling?
This would preclude a split level foyer, unless a properly sloped ramp can be provided....
-
1008.4.1 Turning Space
At least one turning space complying with 304 shall be provided on the same level as play components....