Controls shall be mounted 44 inches (1118 mm) maximum above the finish floor. The force required to activate controls shall be 5 pounds (22.2 mm) maximum.
Search Results "Elongated Water Closet Seat"
Commonly Searched Documents
- 
    
  
  11B-809.10.7.5 Controls
  
 - 
    
  
  11B-610.3.2 L-shaped seats
  
The rear edge of an L-shaped seat shall be 2½ inches (64 mm) maximum and the front edge 15 inches (381 mm) minimum and 16 inches (406 mm) maximum from the seat wall....
 - 
    
  
  604.5.1 Side Wall
  
Figure 604.5.1 Side Wall Grab Bar at Water Closets...
 - 
    
  
  11B-610 Seats
  
[See subsections ...]
 - 
    
  
  604.5.1 Side Wall
  
[ECTCR UFAS 4.17.6, Fig. 30(a), Fig. 30(d)] Figure 604.5.1 Side Wall Grab Bar at Water Closets...
 - 
    
  
  6. Clear floor space
  
6. Clear floor space: Adequate space is provided to approach the toilet from a variety of wheelchair transfer positions (i.e. diagonal or side approaches). Generally, the toilet...
 - 
    
  
  Note
  
Note: In every instance, regardless of toilet and lavatory configuration, adequate space needs to be provided for inmates who use wheelchairs to transfer onto and off of the...
 - 
    
  
  M8
  
M8. Is there at least 18 inches between the center of the toilet and the side of the adjacent lavatory? [ADA Standards § 4.16.2; Fig. 28] Yes No
 - 
    
  
  Length
  
Length. Whereas none of the respondents specifically addressed the issue of grab bar length, drawings submitted clearly indicate that many of the alternate swing away grab bars were...
 - 
    
  
  Lawn Seating: ADA Standard Section 221.5
  
Section 221.5 covers scoping requirements in the current ADA Standards for lawn seating in assembly areas.
 - 
    
  
  Unisex (Single-Use or Family) Toilet and Unisex Bathing Rooms: ADA Standard Section 213.2.1
  
Section 213.2.1 covers scoping requirements in the current ADA Standards for unisex (single-use or family) toilet and unisex bathing rooms.
 - 
    
  
  Fixtures
  
Fixtures TAS 604.3.2 also allows the clear floor space and clearances required at other “fixtures” to overlap the water closet clearance....
 - 
    
  
  11B-213.2.1 Unisex (single-user or family) toilet and unisex (single-user or family) bathing rooms
  
Unisex (single-user or family) toilet rooms shall contain not more than one lavatory, and not more than two water closets without urinals or one water closet and one urinal....
 - Murdock Manufacturing Compact Wall Hung Toilet, Wall Supply
 - 
    
  
  11B-221.5 Lawn seating
  
Lawn seating areas and exterior overflow seating areas, where fixed seats are not provided, shall connect to an accessible route....
 - Mansfield Elementary Two-Piece Toilet 5326-4320
 - 
    
  
  1011.6 Water Spouts
  
Water spouts at water hydrants and water utility hook-ups shall be 28 inches (710 mm) minimum and 36 inches (915 mm) maximum above the ground....
 - 
    
  
  1011.6 Water Spouts
  
Water spouts at water hydrants and water utility hook-ups shall be 28 inches (710 mm) minimum and 36 inches (915 mm) maximum above the ground....
 - 
    
  
  Re: 604.2 Water Closet Location
  
 - 
    
  
  Designated Aisle Seats: ADA Standard Section 221.4
  
Section 221.4 covers scoping requirements in the current ADA Standards for designated aisle seats in assembly areas.
 - 
    
  
  Bathtubs With Permanent Seats: ADA Standard Section 607.4.1
  
Section 607.4.1 covers the current ADA Standards grab bars in bathtubs with permanent seats.
 - 
    
  
  Single-User Toilet Rooms: No Side Transfer Space
  
Single-User Toilet Rooms: No Side Transfer Space On single plumbing walls, lavatories can overlap water closet clear floor space although this precludes side transfers....
 - 
    
  
  11B-610.3 Shower compartment seats
  
When folded, the seat shall extend 6 inches (152 mm) maximum from the mounting wall. Seats shall comply with Section 11B-610.3.1 or 11B-610.3.2....
 - 
    
  
  11B-604.3.2 Overlap
  
The required clearance around the water closet shall be permitted to overlap the water closet, associated grab bars, dispensers, sanitary napkin disposal units, coat hooks, shelves, accessible...