If DOJ amends its ADA regulations as announced in the ANPRM, medical device manufacturers may have an economic incentive to produce accessible products that conform to the standards for...
Search Results "Door Signal Device"
-
Medical Device Manufacturers
-
Issue 15: Installation Errors Increase Risk
Technicians checked the devices more than once and didn’t find any problems. Eventually, the pedestrian and the DOT signal technicians arranged to meet at the site....
-
Section 36.303(g)(1) Captioning Device
“Captioning Device” In the NPRM, at proposed § 36.303(g)(1)(iv), the Department used the term “individual captioning device” to refer to the “individual device that patrons may use at...
-
Maneuvering Clearance: ADA Standard Section 404.3.2
Section 404.3.2 covers the current ADA Standards for maneuvering clearance at automatic and power-assisted doors and gates.
- Otis Elevator Advanced Lantern Retrofit
-
407.3.5 Door Delay
Elevator doors shall remain fully open in response to a car call for 3 seconds minimum....
-
407.3.5 Door Delay
Elevator doors shall remain fully open in response to a car call for 3 seconds minimum....
-
11B-404.3.1 Clear width
The minimum clear width for automatic door systems in a doorway shall provide a clear, unobstructed opening of 32 inches (813 mm) with one leaf positioned at an angle of 90 degrees from...
-
11B-404.3.1 Clear width
The minimum clear width for automatic door systems in a doorway shall provide a clear, unobstructed opening of 32 inches (813 mm) with one leaf positioned at an angle of 90 degrees from...
-
1010.2.2 Hardware
Door handles, pulls, latches, locks and other operating devices on doors required to be accessible by Chapter 11A or 11B shall not require tight grasping, tight pinching or twisting of the...
-
1010.2.2 Hardware
Door handles, pulls, latches, locks and other operating devices on doors required to be accessible by Chapter 11A or 11B shall not require tight grasping, tight pinching or twisting of the...
-
11B-206.5.2 Rooms and spaces
Within a building or facility, every door, doorway or gate serving rooms and spaces complying with this chapter shall comply with Section 11B-404....
-
11B-206.5.2 Rooms and spaces
Within a building or facility, every door, doorway or gate serving rooms and spaces complying with this chapter shall comply with Section 11B-404....
-
11B-407.3.5 Door delay
Elevator doors shall remain fully open in response to a car call for 5 seconds minimum. [2010 ADAS] 407.3.5 Door Delay. ...
-
11B-407.3.5 Door delay
Elevator doors shall remain fully open in response to a car call for 5 seconds minimum. [2010 ADAS] 407.3.5 Door Delay....
-
11B-407.3.5 Door delay
Elevator doors shall remain fully open in response to a car call for 5 seconds minimum. [2010 ADA Standards] 407.3.5 Door Delay....
-
4.13.12* AUTOMATIC DOORS AND POWER-ASSISTED DOORS
If an automatic door is used, then it shall comply with American National Standard for Power-Operated Doors, ANSI A156.10-1979....
-
A4.13.10 Door Closers
They are particularly useful on frequently used interior doors such as entrances to toilet rooms....
-
A4.13.10 DOOR CLOSERS
They are particularly useful on frequently used interior doors such as entrances to toilet rooms....
-
Section 36.303(g)(5) Performance Requirements for Captioning Devices and Audio Description Devices
which devices to purchase....
-
§ 36.303(g)(1)(iv) Captioning device
(iv) Captioning device means the individual device that a patron may use at any seat to view closed movie captioning....
-
§ 36.303(g)(1)(iv) Captioning device
(iv) Captioning device means the individual device that a patron may use at any seat to view closed movie captioning....
-
5.3.5 Doors
Where provided, doors shall comply with ABAAS section 404. The door shall not swing into or otherwise obstruct the clear floor or ground space required by 5.3.2.1....
-
Door Closers [4.13.10]
Door Closers [4.13.10] Because it may be difficult for a person with a disability to open a door against the resistance offered by a closer, it is important that the closing action be...