The term “story” is defined in 106.5.64 as that portion of a building or facility designed for human occupancy included between the upper surface of a floor or the upper surface of the floor...
Search Results "Vehicle Floor Coordination"
Commonly Searched Documents
-
Technical Memorandum TM 2012-04 Multi-Story Buildings and Facilities
-
604.8.1.4 Toe Clearance
The front partition and at least one side partition shall provide a toe clearance of 9 inches (230 mm) minimum above the finish floor and 6 inches (150 mm) deep minimum beyond the compartment-side...
-
404.2.3 Doorways - Clear Width
There shall be no projections into the required clear opening width lower than 34 inches (865 mm) above the finish floor or ground....
-
404.2.3 Doorways - Clear Width
There shall be no projections into the required clear opening width lower than 34 inches (865 mm) above the finish floor or ground....
-
10 - foot straightedge method
10 - foot straightedge method This is the classic method for determining the flatness of concrete and other types of finished floors....
-
11B-404.2.3 Clear width
There shall be no projections into the required clear opening width lower than 34 inches (864 mm) above the finish floor or ground....
-
11B-404.2.3 Clear width
There shall be no projections into the required clear opening width lower than 34 inches (864 mm) above the finish floor or ground....
-
III-4.4100 General
Deep pile carpeting on floors and unpaved exterior ground surfaces often are a barrier to access by people who use wheelchairs and people who use other mobility aids, such as crutches....
-
809.2.5 Bedrooms in Emergency Transportable Housing Units
The clear floor space must be positioned for a parallel approach to the side of the bed and must be on an accessible route....
-
TTYs: ADA Standard Section 217.4
Section 217.4 covers scoping requirements in the current ADA Standards for TTYs.
-
Height: ADA Standard Section 606.3
Section 606.3 covers the current ADA Standards for the height of lavatories and sinks.
-
11B-233.3.4.3 Alterations to residential dwelling units with adaptable features
Exception: Where any portion of a building’s exterior is preserved, but the interior of the building is removed, including all structural portions of floors and ceilings and a new building...
- Activar Hiawatha 5-1/2P Series Pull with Matching Push Plate
- Stanley QRM 100 Series Grade 1 Extra Heavy Duty Exit Devices
-
Section 6.0 Conclusions
Clear floor space: A large minority of participants in our research would not be accommodated by the current U.S. standard for clear floor space, especially for length....
- Waterless Co. No-Flush Urinal Anza 2005
-
[A] ADDITION
[DSA-AC] An expansion, extension, or increase in the gross floor area or height of a building or facility....
-
11B-411.4.8.2.1 Signal type
The signal shall be an automatic verbal annunciator which announces the floor at which the car is about to stop....
-
602.4 Spout Height
Spout outlets shall be 36 inches (915 mm) maximum above the finish floor or ground....
-
602.4 Spout Height
Spout outlets shall be 36 inches (915 mm) maximum above the finish floor or ground....
-
11B-602.4 Spout height
Spout outlets shall be 36 inches (914 mm) maximum above the finish floor or ground....
-
4.24.2 HEIGHT
Sinks shall be mounted with the counter or rim no higher than 34 in (865 mm) from the floor....
-
11B-411.4.8.2.1 Signal type
The signal shall be an automatic verbal annunciator which announces the floor at which the car is about to stop....
-
11B-602.4 Spout height
Spout outlets shall be 36 inches (914 mm) maximum above the finish floor or ground....