However, in order for your uploaded content to be integrated with Corada’s existing database of other accessibility-related material, it must have at least one ADA reference and one keyword...
Search Results "One Step Entry"
-
FAQ: How do I enter keywords in my Voices post?
-
M101.2 Application
Where diagnostic equipment is designed to support more than one patient position, the technical criteria for each patient position supported are to be applied to the equipment....
-
Assistive technology (Preamble, Section-by-Section Analysis)
noted that assistive technology may include screen readers which allow persons who cannot see a visual display to either hear screen content or read the content in Braille, specialized one-handed...
-
§ 35.151(k)(2) Alterations to detention and correctional facilities.
with the 2010 Standards except that public entities shall provide accessible mobility features complying with section 807.2 of the 2010 Standards for a minimum of 3%, but no fewer than one...
-
11B-228.3.2 Minimum number
Where EVCS are provided in more than one facility on a site, the number of EVCS complying with Section 11B-228.3.2 provided on the site shall be calculated according to the number required...
-
11B-404.3.1 Clear width
The minimum clear width for automatic door systems in a doorway shall provide a clear, unobstructed opening of 32 inches (813 mm) with one leaf positioned at an angle of 90 degrees from...
-
11B-1002.5 Amusement ride seats designed for transfer
The proximity of the clear floor or ground space next to an element and the height of the element one is transferring to are both critical for a safe and independent transfer....
-
11B-1002.5 Amusement ride seats designed for transfer
The proximity of the clear floor or ground space next to an element and the height of the element one is transferring to are both critical for a safe and independent transfer....
-
11B-404.3.1 Clear width
The minimum clear width for automatic door systems in a doorway shall provide a clear, unobstructed opening of 32 inches (813 mm) with one leaf positioned at an angle of 90 degrees from...
-
227 Sales and Service
In addition, the final rule restores an exception for smaller facilities that allows one check-out aisle to be accessible (227.2, Exception)....
-
Boat Slips
According to the table, one slip must be accessible, with clear pier space at least 40 feet long and a minimum width of 60 inches....
-
II-6.2100 General
Because of the many differences, one standard is not stricter than the other. Can a public entity follow ADAAG on one floor of a new building and then follow UFAS on the next floor?...
-
Visual Acuity
So one minute is pretty small. If stars are separated by one minute apart, you can see them as two stars, if you have 20/20 vision acuity....
-
Side reach (Section-by-Section Analysis)
Another comment from a person of short stature pointed out that as more businesses take steps to reduce labor costs—a trend expected to continue—staffed booths are being replaced with automatic...
-
Side reach (Section-by-Section Analysis)
Another comment from a person of short stature pointed out that as more businesses take steps to reduce labor costs—a trend expected to continue—staffed booths are being replaced with automatic...
-
Wheelchair Spaces/Companion Seats
Owners of large assembly areas have historically complained to the Department that the requirement for one percent (1%) of seating to be wheelchair seating is excessive and that wheelchair...
-
11B-224.2.2 More than fifty guest room facilities
with a roll-in shower, and one with an accessible bathtub or ADA-compliant transfer-type shower (in which case one of these rooms would be recognized by California as a guest room with...
-
F233.4.1.1 Residential Dwelling Units with Mobility Features
In facilities with residential dwelling units, at least 5 percent, but no fewer than one unit, of the total number of residential dwelling units shall provide mobility features complying...
-
F245.3 Outdoor Constructed Features in Common Use and Public Use Areas
Where provided in common use and public use areas that serve picnic units with mobility features, at least 20 percent, but not less than one, of each type of outdoor constructed feature...
-
212.3 Sinks
Where sinks are provided, at least 5 percent, but no fewer than one, of each type provided in each accessible room or space shall comply with 606....
-
11B-227.4 Food service lines
Where self-service shelves are provided, at least 50 percent, but no fewer than one, of each type provided shall comply with Section 11B-308 _|Reach Ranges|_. ...
-
F244.3 Outdoor Constructed Features in Common Use and Public Use Areas
Where provided in common use and public use areas that serve camping units with mobility features, at least 20 percent, but not less than one, of each type of outdoor constructed feature...
-
Feminine product dispensers
For purposes of resolving this matter, the Museum will provide, on each floor, at least one feminine product dispenser in the women's toilet rooms that does not requires tight grasping and...
-
803.5 Coat Hooks and Shelves
Coat hooks provided within the room shall be located within one of the reach ranges specified in 308....